background image

 

Page 

13

 of 

13

 

Copyright © 2015 P2 Mobile Technologies Limited. All rights reserved. 
 
 

WIRELESS ACCESS POINT USER MANUAL 

 

 

 

 

 

 

 

 

 

P2 Mobile Technologies Limited 

©2015 All rights reserved 

P2MT reserves the right to change, modify, transfer or otherwise revise the publication and the product specifications without notice. 

While P2MT has used commercially reasonable efforts to ensure the accuracy of the specifications contained in this document, P2MT 

assumes no responsibility for any errors or omissions. All scaling metrics outlined in this document are maximum supported values. The 

scale may vary depending upon the deployment scenario and features enabled.

 

 

Summary of Contents for Z500

Page 1: ...mn WIRELESS ACCESS POINT USER MANUAL Z500 P2 Mobile Technologies Limited 2015 All rights reserved ...

Page 2: ...Installation Procedure 6 Installation Environment 6 Pole Mounting Procedure Pole Size Ø40 52mm 6 SmartMoment Configuring the AP 8 Purpose 8 Connection Procedure 8 Wireless Method 8 Wired Method 8 Default Login Information 8 Note 8 Configuring and Monitoring the Access Point 9 Proper Disposal of Product 10 Waste of Electrical and Electronic Equipment 10 European Union RoHS 10 China RoHS 10 Safety a...

Page 3: ...ray vibration extreme thermal conditions shock and dust the IP67 rated Z500 is weather tolerant and is able to deliver uncompromised performance despite extreme environments Supporting 16 isolated SSIDs for each radio Z500 simplifies access policy implementation particularly useful for office environment or retailers who need to separate staff and guest use for security reason Client access to dif...

Page 4: ...fore connecting the access point to the power outlet 9 Use a steady power source to ensure normal functioning 10 Ensure the power adapter is grounded well when installing the access point indoor 11 The lightning protection module inside the device is basic Install any additional protection if necessary 12 Position the power cord so that people cannot step on it Do not place anything over the power...

Page 5: ... Technologies Limited All rights reserved WIRELESS ACCESS POINT USER MANUAL Package Contents Access Point Z500 1 Pole Mounting Kit 1 LAN Port Water proof Connector 1 Inform your supplier if there are any incorrect missing or damaged parts ...

Page 6: ...us Steady Green Integrated 2 4 GHz radio is enabled Off Integrated 2 4 GHz radio is disabled Radio 1 External 5 GHz Radio Status Steady Green External 5 GHz radio is enabled Off External 5 GHz radio is disabled 3 External Antennas Connectors Through the N Type connector the access point can be connected with various types of antenna for optimized results of different deployment scenarios Note AP t...

Page 7: ...rocedure Pole Size Ø40 52mm 1 Firstly install the L shaped clamp with M6 screw nut spring washer and flat washer Four screws need be installed 2 Put the U shaped screw stem and U shaped slot into the hole And then drive the M6 crew nut and M6 washer 3 Install the clamp on the back of the AP with M6 12 screw bolt M6 spring washer and M6 flat washer Four screw bolts need be installed 4 Input M6 12 s...

Page 8: ... of 13 Copyright 2015 P2 Mobile Technologies Limited All rights reserved WIRELESS ACCESS POINT USER MANUAL 5 Finally mount the AP on the pole as shown in the picture And drive the screw nut tight with wrench ...

Page 9: ...tion Procedure Wireless Method 1 Power up the AP 2 Use a Wi Fi enabled device to connect to the SSID P2MTWifi with password p2mtuser 3 Open the browser and type the IP address 172 16 0 1 4 Navigate to the top menu bar and click Lightweight under Mode Wired Method 1 Power up the AP 2 Connect the AP and the PC with a LAN cable 3 Set the IP of the PC to 192 168 1 2 4 Navigate to SmartMoment by 192 16...

Page 10: ...like a WLAN controller or so called access controller the MeshProvision Server is NOT required to be running for the wireless network to operate In other words it can be shut down without affecting the wireless network at all Therefore it will never be the Single Point Of Failure by any means The Z500 supports traffic monitoring configuration broadcast map configuration and email notification for ...

Page 11: ...uropean Union RoHS EU Restriction and Hazardous Substances Directive 2011 65 EC RoHS restricts the use of specific hazardous materials in manufacture of electrical and electronic equipment Specially restricted materials are Lead Cadmium Mercury Hexavalent Chromium and Bromine The Z500 AP complies with this requirement and all marked with RoHS shown at the left China RoHS The Z500 AP complies with ...

Page 12: ... these substances may be found in the supply chain of P2MT electronic information products as of the date of sale of the enclosed product Note that some of the component types listed above may or may not be a part of the enclosed product 除非另外特别的标注 此标志为针对所涉及产品的环保使用期标志 某些零部件会 有一个不同的环保使用期贴在其产品上 此环保使用期限只适用于产品是在产品手册中 规定的条件下工作 The Environment Friendly Use Period EFUP for all enclosed products and their ...

Page 13: ...ator is off Check that the power adapter is plugged into a live AC outlet Check the power cable for shorts or breaks Check whether the connection between the LAN PoE port of the combiner and the LAN PoE port is correct The LAN port indicator is off Check whether the connection between the LAN PoE port of the combiner and the LAN PoE port is correct End of User Guide ...

Page 14: ...r or otherwise revise the publication and the product specifications without notice While P2MT has used commercially reasonable efforts to ensure the accuracy of the specifications contained in this document P2MT assumes no responsibility for any errors or omissions All scaling metrics outlined in this document are maximum supported values The scale may vary depending upon the deployment scenario ...

Page 15: ...eorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not ca...

Reviews: