background image

         

  

 

                                 

www.pmlighting.com 

  

                [email protected]  

 

To clarify installation and wiring of your 100 watt Professional Series power transformer, please refer to 

the instructions below. 

 

1) USE ONLY THE BOTTOM SCREW TERMINALS TO ATTACH THE MAIN CABLES FROM THE LIGHT FIXTURE 

RUNS. 

DO NOT LOOSEN TOP SCREWS OR REMOVE WIRES ATTACHED TO THE TOP SCREWS

 

2) 

EACH MAIN CABLE RUN MUST BE CONNECTED TO 1 (LEFT) AND 2 (RIGHT).

 SEE DIAGRAM BELOW 

(SHOWING UP TO 2 MAIN CABLE RUNS). 

 

3) ATTACH ONE SIDE OF THE MAIN CABLE RUN TO THE LEFT TERMINAL (1) BY INSERTING THE STRIPPED 

WIRE (APPROX. ¾”) INTO THE BOTTOM OF THE TERMINAL BLOCK. ATTACH THE OTHER SIDE OF THE 

MAIN CABLE RUN TO THE RIGHT TERMINAL (2). TIGHTEN BOTTOM TERMINAL SCREWS TO SECURE EACH 

WIRE. 

 

 

    

      

 

 

 

CS12100 Professional

 

Series

 

Landscape Lighting System 

– 

pg. 9

 

Transformer Terminal Block 

Insert one side of each main cable run into the bottom of the terminal block 

in the (1) LEFT screw terminal and one side in the (2) RIGHT screw terminal.  

CAUTION: 

DO NOT LOOSEN TOP 

SCREWS OR REMOVE ANY WIRES IN 

TOP PORTION OF TERMINAL BLOCK! 

1L 

2R 

Summary of Contents for CS12100-LED

Page 1: ...www pmlighting com info pmlighting com Installation Manual CS12100 LED Professional Series Landscape Lighting System ...

Page 2: ...andscape lighting is quite easy to install and is much easier than traditional halogen systems LED lighting allows the running of cables with less complications of the dreaded voltage drop that occurs more readily with halogen systems and other higher wattage incandescent systems Just follow these four easy steps for a successful installation A Determine the location of the power transformer befor...

Page 3: ...ly installed and are making a good connection 4 Use the HIGH SETTING on the transformer to boost the secondary voltage for this system to provide additional voltage See detailsin Transformer Installation Sheet 5 SHORTER lengths for the MAIN SUPPLY CABLE lowers voltage drop on the line while LONGER lengths increases the voltage drop Use the Line Length Wattage Chart below to determine the maximum w...

Page 4: ...rom the transformer to split the fixtures into two 2 groups For best results follow these tips 1 Keep cables as short as possible 2 Leave enough slack to make burying cable easier 3 Make sure the Easy Connectors are tight to create a good connection on the Main Supply Cable CS936 LED 3W CS937 LED 5W CS12100 Professional Series LED Landscape Lighting System pg 3 CS933 LED 6W ...

Page 5: ...naire away from children as luminaire may become VERY HOT Do not install luminaire within 10 feet 3 05 meters of a pool spa fountain or pond Do not cover or bury luminaire and keep luminaire clear of debris Use only UL compliant components includinglow voltage power units cable wire connectors and any other component necessary CAUTION Luminaire is NOT submersible NOTE Do not exceed the maximum wat...

Page 6: ... VERY HOT Do not install luminaire within 10 feet 3 05 meters of a pool spa fountain or pond Do not cover or bury luminaire and keep luminaire clear of debris Use only UL compliant components includinglow voltage power units cable wire connectors and any other component necessary CAUTION Luminaire is NOT submersible NOTE Do not exceed the maximum wattage rating or maximum amperage rating of the po...

Page 7: ...om combustibles Lamp gets hot very quickly Turn off or unplug luminaire and allow lamp to cool to change bulb When using high wattage lamps keep luminaire away from children as luminaire may become VERY HOT Do not install luminaire within 10 feet 3 05 meters of a pool spa fountain or pond Do not bury luminaire below the recommended depth and keep luminaire clear of debris Use only UL compliant com...

Page 8: ... Cut the old Quick Connect parts from the wires if replacing old ones and strip the end of the wires to approximately in length 2 Use the wire nuts included in the replacement kit to connect each side of the Quick Connect to the 18 gauge wire on the luminaire 3 Attach and secure the new Quick Connect as outlined above CS12100 Professional Series Landscape Lighting System pg 7 LEFT PICTURE Slide th...

Page 9: ...www pmlighting com info pmlighting com CS12100 Professional Series Landscape Lighting System pg 8 ...

Page 10: ...WING UP TO 2 MAIN CABLE RUNS 3 ATTACH ONE SIDE OF THE MAIN CABLE RUN TO THE LEFT TERMINAL 1 BY INSERTING THE STRIPPED WIRE APPROX INTO THE BOTTOM OF THE TERMINAL BLOCK ATTACH THE OTHER SIDE OF THE MAIN CABLE RUN TO THE RIGHT TERMINAL 2 TIGHTEN BOTTOM TERMINAL SCREWS TO SECURE EACH WIRE CS12100 Professional Series Landscape Lighting System pg 9 Transformer Terminal Block Insert one side of each mai...

Page 11: ...www pmlighting com info pmlighting com CS12100 Professional Series Landscape Lighting System pg 10 ...

Page 12: ...www pmlighting com info pmlighting com P O Box 98 Ashland City TN 37015 Phone 615 792 6884 Fax 615 792 6898 2019 P M Lighting LLC All Rights Reserved ...

Reviews: