*CAUTION: UNPLUG POWER SUPPLY TO OzotechEOG BEFORE
PERFORMING SERVICE*
1. With the front cover removed, remove the CD cell from the
ozone generator:
a. Disconnect the red spade terminal connector from the
CD cell connection terminal.
b. Cut the CD cell retaining strap holding the cell into the
cell clips, and discard.
c. Disconnect the air inlet and ozone outlet hoses from
the CD cell barb fittings.
d. Pull the CD cell straight up from the retaining clips.
2. Flush the CD cell with warm water until the water comes out
entirely clean:
a. Connect a 3/16” I.D. piece of tubing to either of the CD
cell barb fittings.
b. Using a syringe or rubber bulb pump to work the warm
water through the CD cell, flushing until all nitric acid
or obstructions are removed, and the water runs clean.
(NOTE: Hot water can be used if nitric acid buildup is severe)
3. Ensure that the CD cell is completely dry, inside and out, before
re-installation:
a. Use dry, compressed air to blow through either CD
cell barbed fitting until no moisture is ejected from the
opposite barbed fitting.
5.1 Ozone Generator Maintenance Cont.
10.