9. Pressure check your unit.
a. With the unit powered down and a source of positive pressure flowing into the unit,
open the airflow meter until the indicating ball reaches the top of the scale.
b. Remove the ozone delivery tubing from the venturi injector inlet (or equivalent) and
seal to pressurize the generator and ozone delivery tubing.
c. Using a suitable leak check solution (available through your Ozotech, Inc., dealer) check
for leaks at the tube/chamber interface, tubing connections, etc. Immediately correct
any leaks prior to placing your unit back in service.