![Ozotech AIM BTU 1000 Installation And Service Manual Download Page 16](http://html.mh-extra.com/html/ozotech/aim-btu-1000/aim-btu-1000_installation-and-service-manual_1667158016.webp)
M43-31334&5 REV A
System
Possible Cause
Solution
Corona Discharge Cell(s) were not installed. Install cell(s) per Quick Start Guide.
corona discharge cells are shipping
in separate boxes to avoid shipping
damage.
Corona outside of the manifold has estab-
lished due to dirt, moisture, or improper
wire routing.
Corona Discharge Cell may be in need of
maintenance.
Perform corona discharge cell
maintenance procedure found in
section 3.1.
Replace any defective
components before placing unit
back into service.
Unit does not produce adequate
concentration of ozone.
Air flow rate is too high.
Adjust air flow meter to lower
setting, within range of specified
Air Flow Specifications, found in
section 2.2.
Unit is running to hot due to insufficient
cooling air flow
Refer to the Air Flow Specifications,
section 2.2.
Ensure intake air filter is clean, dry
and undamaged. Perform any
necessary maintenance before plac-
ing unit back into service.
Unit is connected to improper power
source.
Refer to Input Power Requirements,
section 2.4, or power rating label on
side of chassis for proper electrical
requirements.
Connect unit to proper power
source.
Unit does not produce adequate
concentration of ozone, even with
an air flow rate that previously
produced adequate ozone con-
centration.
Corona Discharge Cells require mainte-
nance.
Refer to section 3.1 for corona
discharge cell maintenance.
Air preparation device is not functioning at
prior level or performance.
Inspect and/or maintain air
preparation equipment in accor-
dance with manufacturer
Water has backed up into the
ozone unit
Failed or missing in-line check valve or BF-1
on ozone output tubing.
Thoroughly dry manifold and
tubing.
Clean or replace CD cell.
Replace or install a new in-line
check valve and/or BF-1, as appli-
cable.
12
Summary of Contents for AIM BTU 1000
Page 1: ...AIM BTU 1000 2000 Ozone Generators Installation and Service Manual M43 31334 5 REV A ...
Page 10: ...M43 31334 5 REV A 6 Figure 2 CD Cell Cap Removal and Installation ...
Page 11: ...M43 31334 5 REV A 7 Figure 3 CD Cell Manifold Assembly ...
Page 18: ...M43 31334 5 REV A Figure 8 Left Side Interior View Figure 7 Front Interior View 14 ...
Page 19: ...M43 31334 5 REV A Figure 9 Right Side Interior View 15 ...
Page 20: ...M43 31334 5 REV A Figure 10 AIM BTU 1000 2000 Wiring Diagram 16 ...
Page 23: ...Ozotech Inc 1015 South Main Street Yreka CA 96097 Ph 530 842 4189 ozotech com ...