AM5000 Doc. No. 290-062-00 rev. A June 2005
d) Connecting the generator:
Plug the generator into the socket of the timer and insert the timer into a
socket outlet. Ensure the outlet socket is switched on.
e) Timed switching:
Ensure the red slide switch on the side of the timer is set to the centre (AUTO)
position, with the clock face symbol.
f) Manual override:
To switch the plugged in generator permanently on, set the red slide switch on
the side of the timer to the ‘1’ ON position.
To switch the plugged in generator permanently off, set the red slide switch on
the side of the timer to the ‘0’ ON position.
Usage
–Important
The timer is rated at 13 Amps (resistive load) and 4 Amps (inductive load).
If you have any queries regarding the operation of the various control panels
please contact your supplier.
6.0 MAINTENANCE AND SERVICING.
The exterior of the unit requires an occasional wipe with a damp cloth to maintain
its appearance, do not use abrasives.
Servicing of the unit must be carried out by a competent person who has read and
understood the instructions.
The service frequency will vary depending upon the output setting and the
environments in which the unit has been used in.
A guide to maintenance and service of the unit is:
6.1 Weekly:
Check the operation of the fan.
Switch on the power supply to the unit.
Check that the fan is rotating freely. If the fan is faulty please refer to the
Annual service section for details on how to replace it.
6.2 Three Monthly:
Check and clean the inside of the unit.
Isolate the mains supply to the unit.
Remove the lid of the unit by undoing (anti-clockwise) the 8 quarter turn
fasteners.