AM5000 Doc No. 290-062-00 Rev. A June 2005
5.2 Control Options.
The operation of the unit will vary depending upon the type of control panel fitted.
These instructions describe how to operate the unit with the various options.
The following information is common to all control panels:
Ensure doors and windows of the room to be treated are closed and place
warning notices stating “CAUTION THIS ROOM IS BEING OZONISED DO
NOT ENTER BETWEEN XX O’CLOCK AND XX O’CLOCK” at the entrances.
If you need to enter an Ozonised room with a high Ozone concentration, use a
mask. A suitable Ozone mask is
3M Respirator type 9925.
NOTE: the time spent in the room must be kept to a minimum.
The Ozone will change back to Oxygen within 3 hours when the recommended
settings are used. After this time it is safe to enter the room without a mask.
This decay period must be allowed for when calculating the time it is safe to
return to the room.
If the desired result is not achieved completely in the first instance, the process
can be repeated as many times as is required until the desired results are
achieved.
5.2.1 Two Hour Countdown Control Panel.
Set the timer to the desired duration, up to a maximum of two hours.
Connect the unit to the electrical supply and start treatment.
Once the timer duration has completed the unit will turn itself off.