3.0 UNIT DESCRIPTION

 

The AM5000 series of generator is designed to convert Oxygen found in 
the normal air into Ozone. It does this using the Corona Discharge (CD) 
principle, where air is blown over a ceramic plate with a stainless steel 
electrode, known as an open cell. Each cell has its own power supply, 
which delivers high voltage, high frequency electricity to the cell. Each 
cell is capable of producing up to 1g/hr of Ozone. 
The unit is available in two sizes, the AM5100 and the AM5200.  
AM5100 is a single cell design. 
AM5200 is a double cell design. 
See section 9.0 for more detailed specifications of the units. 
 

4.0 INSTALLATION 

These Ozone generators are primarily designed as a portable unit which 
is supplied with a UK 3 pin plug, fitted with a 3 Amp fuse and only 
requires a 13 Amp 230V 50Hz switched power supply. All electrical 
connections should comply with current IEE wiring regulations (BS 
7671: 1992 or equivalent). 
There are a few guidelines to positioning the unit in order to maximise 
its effectiveness: 

  On a flat, vibration free surface. 

  Centrally in the area to be treated and if possible at approximately 

table height. 

  The airflow around the unit should not be restricted, a minimum 

clearance of 800mm around the unit is recommended. 

  There should be no risk of the unit being splashed with water, or 

other liquids. 

  The temperature s

hould be between 0ºC to +30ºC. 

 

The relative humidity should not exceed 75% at 20ºC, non-
condensing. 

  The environment should contain no combustible gases or 

aggressive/corrosive chemicals such as bleach, bromine or similar. 

 
Additional fixings are available 

separately, to allow connection to a 4” 

ducting set-up and Heating, Ventilation and Air Conditioning (HVAC) 
ducting. Instructions on how to fit these are supplied with the parts.

Summary of Contents for AM5000 Series

Page 1: ...INTENANCE INSTRUCTIONS FOR MODELS AM5100 AM5101 AM5200 AM5201 Model Specifications AM5100 1gm hr output AM5101 1gm hr output with countdown timer AM5200 2gm hr output AM5201 2gm hr output with countdo...

Page 2: ...grams per hour g hr of Ozone NOTE The ozone generator contains brittle ceramic plates and must not be knocked dropped or subjected to vibration 1 0 HEALTH AND SAFETY Ozone is an irritant and a powerfu...

Page 3: ...nd only requires a 13 Amp 230V 50Hz switched power supply All electrical connections should comply with current IEE wiring regulations BS 7671 1992 or equivalent There are a few guidelines to position...

Page 4: ...zone generator is run and the output setting Any ventilation installed may reduce the effectiveness of your ozone generator The output can be set as follows a 100 output with the countdown timer for u...

Page 5: ...A suitable Ozone mask is 3M Respirator type 9925 NOTE the time spent in the room must be kept to a minimum The Ozone will change back to Oxygen within 3 hours when the recommended settings are used Af...

Page 6: ...lug the timer before setting times The timer will turn the unit on and off up to 48 times per day a Setting switch OFF times With your finger pen or small screwdriver pull up segments corresponding to...

Page 7: ...egarding the operation of the various control panels please contact your supplier 6 0 MAINTENANCE AND SERVICING The exterior of the unit requires an occasional wipe with a damp cloth to maintain its a...

Page 8: ...e take care when removing the lid not to stress the lead Check the overall condition inside the unit and remove any debris Check that all the electrical connections are in good condition Unplug the re...

Page 9: ...AM5000 Doc No 290 062 00 rev A June 2005 GENERATOR FAN PLATE ASSEMBLY PLATE SUPPORT BRACKET CLEAN THIS SURFACE ENSURING ALL DEPOSITS ARE REMOVED...

Page 10: ...cell s No airflow through unit Fan not connected Fan faulty Filter blocked if fitted Check and correct Replace fan Clean or replace filter 8 0 SPARE PARTS Description Model Stock No Generator Cell Ass...

Page 11: ...is 300m3 From the chart the unit can be set at any level to be effective at removing odours The stronger the odour the higher the setting If the room to be treated is clear of people at 18 00hrs and...

Reviews: