AM5000   Doc. No. 290-062-00 rev. A    June 2005 

Appendix A 

 

SETTING GUIDE 

 
1)  Calculate the room volume (length x width x height) 
 
2)  Set the output of the machine to suit the room size and odour by altering the timer.  
 
3)  Each segment on the timer is equivalent to 15 minutes.  
      For example, to run the generator for 30 minutes per hour for 2 hours: (a) push down two segements at the   
      time setting you want the generator to start; (b) leave the next two segments "up"; c) push down the next   
      two segments. 
 
4)   Do not enter the treated room until at least 

two hours 

after the ozone generator has stopped. 

 
Example 
     A room measures 20m x 5m x 3m. So its volume is 300m

     From the chart, the unit can be set at any level to be effective at removing odours. The stronger the odour   
     the higher the setting. 
 
     If the room to be treated is clear of people at 18.00hrs and access is not needed until 07:00hrs the following   
     morning, the timer should be programmed to turn on at 19:00hrs, run for 9 hours and turn off at 04:00hrs the   
     following morning. 
 
     This will allow 3 hours for the room to be safe to enter. 
     The warning signs on the entrances should state that the room should not be entered between 18:00hrs and   
      07:00hrs. 

 

 

 

 

 

 

 

 

ROOM 

VOLUME 

timer setting (mins per hour) 

m

 

15 

30 

60 

 

100 

 





 

150 

 





 

200 

 







 

300 

 







 

400 

 







 

500 

 







 

600 

 







 

700 

 







 

800 

 







 

900 

 







 

1000 

 







 

1500 

 







 

2000 

 







 

 

 

 

 

 

 

Note

 

 

 

 

 

15 minutes = 1 segment in 4 

 

30 minutes = 2 timer segments in 4 
60 minutes = 4 timer segments in 4 

 

 

 

NOT RECOMMENDED 

 



RECOMMENDED 

 



OZONE LEVEL TOO LOW TO BE EFFECTIVE 

 

Summary of Contents for AM5000 Series

Page 1: ...INTENANCE INSTRUCTIONS FOR MODELS AM5100 AM5101 AM5200 AM5201 Model Specifications AM5100 1gm hr output AM5101 1gm hr output with countdown timer AM5200 2gm hr output AM5201 2gm hr output with countdo...

Page 2: ...grams per hour g hr of Ozone NOTE The ozone generator contains brittle ceramic plates and must not be knocked dropped or subjected to vibration 1 0 HEALTH AND SAFETY Ozone is an irritant and a powerfu...

Page 3: ...nd only requires a 13 Amp 230V 50Hz switched power supply All electrical connections should comply with current IEE wiring regulations BS 7671 1992 or equivalent There are a few guidelines to position...

Page 4: ...zone generator is run and the output setting Any ventilation installed may reduce the effectiveness of your ozone generator The output can be set as follows a 100 output with the countdown timer for u...

Page 5: ...A suitable Ozone mask is 3M Respirator type 9925 NOTE the time spent in the room must be kept to a minimum The Ozone will change back to Oxygen within 3 hours when the recommended settings are used Af...

Page 6: ...lug the timer before setting times The timer will turn the unit on and off up to 48 times per day a Setting switch OFF times With your finger pen or small screwdriver pull up segments corresponding to...

Page 7: ...egarding the operation of the various control panels please contact your supplier 6 0 MAINTENANCE AND SERVICING The exterior of the unit requires an occasional wipe with a damp cloth to maintain its a...

Page 8: ...e take care when removing the lid not to stress the lead Check the overall condition inside the unit and remove any debris Check that all the electrical connections are in good condition Unplug the re...

Page 9: ...AM5000 Doc No 290 062 00 rev A June 2005 GENERATOR FAN PLATE ASSEMBLY PLATE SUPPORT BRACKET CLEAN THIS SURFACE ENSURING ALL DEPOSITS ARE REMOVED...

Page 10: ...cell s No airflow through unit Fan not connected Fan faulty Filter blocked if fitted Check and correct Replace fan Clean or replace filter 8 0 SPARE PARTS Description Model Stock No Generator Cell Ass...

Page 11: ...is 300m3 From the chart the unit can be set at any level to be effective at removing odours The stronger the odour the higher the setting If the room to be treated is clear of people at 18 00hrs and...

Reviews: