Ozone AM5000 Series Installation, Operating, Maintenance Download Page 1

AM5000  Doc No. 290-062-00 Rev. A  June 2005 

 
 
 
 

 
 
 
 
 
 
 

INSTALLATION, OPERATING & MAINTENANCE  

 

INSTRUCTIONS FOR MODELS 

 

AM5100, AM5101, AM5200 

AM5201 

 
 
 
 

Model Specifications: 
AM5100   -   1gm/hr output 
AM5101   -   1gm/hr output with countdown timer 
AM5200   -   2gm/hr output 
AM5201   -   2gm/hr output with countdown timer  

 
 
 
 
 
 
 

For settings see appendix A 

 
 
 
 

AM5000 

 

SERIES 

Ozone Generator 

 

Summary of Contents for AM5000 Series

Page 1: ...INTENANCE INSTRUCTIONS FOR MODELS AM5100 AM5101 AM5200 AM5201 Model Specifications AM5100 1gm hr output AM5101 1gm hr output with countdown timer AM5200 2gm hr output AM5201 2gm hr output with countdo...

Page 2: ...grams per hour g hr of Ozone NOTE The ozone generator contains brittle ceramic plates and must not be knocked dropped or subjected to vibration 1 0 HEALTH AND SAFETY Ozone is an irritant and a powerfu...

Page 3: ...nd only requires a 13 Amp 230V 50Hz switched power supply All electrical connections should comply with current IEE wiring regulations BS 7671 1992 or equivalent There are a few guidelines to position...

Page 4: ...zone generator is run and the output setting Any ventilation installed may reduce the effectiveness of your ozone generator The output can be set as follows a 100 output with the countdown timer for u...

Page 5: ...A suitable Ozone mask is 3M Respirator type 9925 NOTE the time spent in the room must be kept to a minimum The Ozone will change back to Oxygen within 3 hours when the recommended settings are used Af...

Page 6: ...lug the timer before setting times The timer will turn the unit on and off up to 48 times per day a Setting switch OFF times With your finger pen or small screwdriver pull up segments corresponding to...

Page 7: ...egarding the operation of the various control panels please contact your supplier 6 0 MAINTENANCE AND SERVICING The exterior of the unit requires an occasional wipe with a damp cloth to maintain its a...

Page 8: ...e take care when removing the lid not to stress the lead Check the overall condition inside the unit and remove any debris Check that all the electrical connections are in good condition Unplug the re...

Page 9: ...AM5000 Doc No 290 062 00 rev A June 2005 GENERATOR FAN PLATE ASSEMBLY PLATE SUPPORT BRACKET CLEAN THIS SURFACE ENSURING ALL DEPOSITS ARE REMOVED...

Page 10: ...cell s No airflow through unit Fan not connected Fan faulty Filter blocked if fitted Check and correct Replace fan Clean or replace filter 8 0 SPARE PARTS Description Model Stock No Generator Cell Ass...

Page 11: ...is 300m3 From the chart the unit can be set at any level to be effective at removing odours The stronger the odour the higher the setting If the room to be treated is clear of people at 18 00hrs and...