background image

2.  L-SHAPE CONNECTOR

3.  FLOAT SWITCH

3.   Screw the prepared 

universal adaptor clockwise 

onto the L-shape connector 

NOTE. 

The hose/tube/

tap adaptor should not be 

connected at this stage.

4.   Securely attach the hose/

tube/tap adaptor to the 

universal adaptor, fit hose 

clamps if you are using Lay 

flat hose or tube, and tighten 

well.

2.   Make sure the L-shape 

connector is firmly 

tightened so that the 

O-ring is compressed 

between the pump 

housing and the 

L-shape connector.  

This ensures no leakage 

will occur at this point.

OPERATION

 The pump is fitted with a float switch, which controls how 

the pump switches on and switches off.

Automatic mode 

1.   Screw the L-shape 

connector into the pump 

housing by rotating in a 

clockwise direction. 

4.   When the float switch cable is 

extended fully the pump will 

function down to a water depth 

of 50mm and automatically 

shut off.

3.   To set the pump to switch 

off at a higher water level, 

adjust the float switch cable 

length in the adjuster.

100mm

minimum

 

 NOTE:

 There must be a 

minimum of 100mm of cable 

from the adjuster to the float. 

1.   When the float switch is 

about 30° higher than 

horizontal (start up level) or 

above the handle, the pump 

will turn ‘on’ and operate 

(water depth of 500mm).

30°

30°

2.   When the float switch is 30° 

lower than the horizontal or 

below the handle, the pump 

will turn ‘off’. (water depth of 

approximately 150mm)

1.   When the float switch is held in 

the vertical position the pump will 

run continuously.

CAUTION:

  

To prevent the pump 

running dry, this operating mode 

is only allowed under supervision. 

The pump must be switched off as 

soon as no more water is emitted 

from the discharge line.

 Manual operation

When the pump is plugged into an outlet and left unattended it will 

turn on when the float switch turns on.

Summary of Contents for PSDWK-1000

Page 1: ... defects caused by or resulting from abuse accidents or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE...

Page 2: ...lamp ACCESSORIES SETUP PREPARATION To fit a 25mm 1 tap adaptor temporary application only 1 Cut the universal adaptor using a hack saw not included Ensure all flashing is removed 2 It is now ready to be fitted with a 25mm 1 screw on tap adaptor not included To fit a 32mm 1 flexible tubing Cut the universal adaptor using a hack saw It is now ready to be fitted with a 32mm 1 rigid pipe or flexible t...

Page 3: ... the pump will function down to a water depth of 50mm and automatically shut off 3 To set the pump to switch off at a higher water level adjust the float switch cable length in the adjuster 100mm minimum NOTE There must be a minimum of 100mm of cable from the adjuster to the float 1 When the float switch is about 30 higher than horizontal start up level or above the handle the pump will turn on an...

Page 4: ...urface there are no obstructions to the suction base and out of mud or sediment 1 Immerse the pump in the water For deep water use the rope and secure it to the handle Set the pump in the desired position within the work area or tank NOTE Ensure any connections remain above water level 2 Insert the plug into the mains power socket Where possible avoid using extension cords as this can lead to a vo...

Page 5: ...ly obstructed blocked The hose tube is obstructed Air leak in the suction line or joints Incorrect assembly leads to air and water leakage in the discharge lines Reduce below the max head immersion rating Clean the suction base of any foreign matter and debris Remove the obstructions Check the suction line connections for air leaks and tighten or fix where found Ensure the discharge lines are the ...

Page 6: ...ave your pump serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the pump is maintained b If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard GENERAL SAFETY WARNINGS ELECTRICAL SAFETY WARNING This product is intended for pumping water in a Home...