background image

INSTALLATION

TROUBLESHOOTING

Discharge point

Max. 

head:

 

9m

Max. 

immersion 

depth: 7m

Water level

Pump

Water container

Power cable: 10m

Problem

Possible Cause

Solution

 

The pump does not start,  

or pump water

 

Pump is not connected to the power supply 

 

Float switch has not been activated, water 

level too low 

The impellor is stuck
 

The thermal overload protection is activated 

 

The motor is damaged

 

Check that the pump is connected to the mains power supply 

 

Manually raise the position of the float switch 

 

Turn pump off and inspect and clean obstruction

 

Wait for the motor to cool and it will automatically start operation 

 

 

Contact Ozito customer service

 

The pump does not supply water 

when the motor is running

 

The suction base is obstructed/blocked 

Air lock in the hose/tube and/or pump (air 

bubbles) 

Discharge hose/tube is kinked  damaged or 

blocked.

 

Clean the suction base of any foreign matter and debris

 

 

Perform several start-ups in order to remove all the air or lift and tilt the pump slightly while the 

pump is running 

Un-kink the discharge hose/tube. Or replace hose/tube 

Disconnect the mains power and check the discharge outlet for any foreign matter

 

The pump flow rate is reduced

 

The max head / immersion is exceeded 

 

The suction base is partially obstructed/

blocked 

 

The hose/tube is obstructed 

 

Air leak in the suction line or joints 

Incorrect assembly leads to air and water 

leakage in the discharge lines

 

Reduce below the max head / immersion rating. 

 

Clean the suction base of any foreign matter and debris

 

 

 

Remove the obstructions 

 

Check the suction line connections for air leaks and tighten or fix where found

 

 

Ensure the discharge lines are the correct length and all assembly instructions are adhered to

 

Pump will not turn off, even 

though the water level is low

 

The float switch is stuck in the “on” position

 

 

Ensure that the float switch is free to operate normally. Contact Ozito customer service if the 

problem still occurs 

Hose/tube does not stay on the 

universal adaptor when water is 

travelling through

The hose/tube is slightly wider than the 

dimension of the universal adaptor

An adhesive can be used inside the hose/tube to prevent this or Teflon tape can be fixed 

around the universal adaptor or a hose clamp can be used

The pump operates intermittently

The suction base is obstructed/blocked 

 

Incorrect voltage is being used 

 

The fluid contains particles thicker than 20mm

 

 

The motor is faulty or damaged

 

 

Water level is below 50mm

 

Clean the suction base of any foreign matter and debris

 

 

Ensure the pump is connected into 230-240V power supply 

 

Ensure the pump is not being used with particles thicker than 20mm. 

 

Contact Ozito customer service

 

 

Ensure the water level is above 50mm

Summary of Contents for PSDWK-1000

Page 1: ... defects caused by or resulting from abuse accidents or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE...

Page 2: ...lamp ACCESSORIES SETUP PREPARATION To fit a 25mm 1 tap adaptor temporary application only 1 Cut the universal adaptor using a hack saw not included Ensure all flashing is removed 2 It is now ready to be fitted with a 25mm 1 screw on tap adaptor not included To fit a 32mm 1 flexible tubing Cut the universal adaptor using a hack saw It is now ready to be fitted with a 32mm 1 rigid pipe or flexible t...

Page 3: ... the pump will function down to a water depth of 50mm and automatically shut off 3 To set the pump to switch off at a higher water level adjust the float switch cable length in the adjuster 100mm minimum NOTE There must be a minimum of 100mm of cable from the adjuster to the float 1 When the float switch is about 30 higher than horizontal start up level or above the handle the pump will turn on an...

Page 4: ...urface there are no obstructions to the suction base and out of mud or sediment 1 Immerse the pump in the water For deep water use the rope and secure it to the handle Set the pump in the desired position within the work area or tank NOTE Ensure any connections remain above water level 2 Insert the plug into the mains power socket Where possible avoid using extension cords as this can lead to a vo...

Page 5: ...ly obstructed blocked The hose tube is obstructed Air leak in the suction line or joints Incorrect assembly leads to air and water leakage in the discharge lines Reduce below the max head immersion rating Clean the suction base of any foreign matter and debris Remove the obstructions Check the suction line connections for air leaks and tighten or fix where found Ensure the discharge lines are the ...

Page 6: ...ave your pump serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the pump is maintained b If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard GENERAL SAFETY WARNINGS ELECTRICAL SAFETY WARNING This product is intended for pumping water in a Home...