OPERATION (cont.)
12
Note:
Movement of the chain through the chain clamp (sliding guide) should be
from the HANGING chain as shown. Movement of the chain should NOT be from
the top of the clamp area.
To move the chain, the clamp lever (13) should be loosened then gently pull
downwards on the hanging chain. After the tooth to be sharpened has passed
under the stop, gently pull the chain via the hanging chain to the left until the stop
locates the chain tooth.
Always select the correct orientated tooth for the set up for the table.
Sharpening teeth in opposite direction
1. Ensure the sharpener is turned off and the disc is not rotating.
2. Check the angle of the table of the current setting, loosen the angle locking
knob (10), and rotate the table to the opposite side, but to the same
corresponding angle.
3. Lock the angle locking knob firmly.
4. Using the same method above, release the clamping lever and move the chain to
the right and locate the first chain tooth with the opposite orientation from the
first sharpening process. The settings should be the same, however when making
the first cut always take care and check the amount being cut off the tooth, and
also the depth of the cut. Check both of these settings and adjust accordingly.
Removing a disc
1. Disconnect the sharpener from the power supply.
2. Remove the 3 screws holding the disc cover to the sharpener housing.
3. Lift off the cover.
4. Hold the disc with one hand and using the free hand turn the knob at the
centre of the disc anti clockwise. Remove the knob.
5. Remove the disc and replace with a new one.
Fitting a disc
1. Replace a new disc over the spindle.
2. Replace the locking knob and screw clockwise (hold the disc with the free
hand to ensure the locking knob can be tightened properly).
3. Replace the cover.
4. Secure cover by fixing the 3 screws through the cover back into the sharpener housing.