background image

OPERATION

2.  CONTROLS

2.   To turn off, slide the 

switch backwards.

2.   Place the circular end of the dust collection adaptor over the 

accessory spindle so that the adaptor rests against the bottom 

of the tool handle. Push the securing clip over the power cord 

to secure in place.

3.   Connect a vacuum or dust extractor hose to the hose 

connector.

1.   To turn on, slide the 

on/ off switch forward.

1.   Push the parts of the dust collection accessory together.

The dust collection adaptor can be fitted to your multi function 

tool to reduce the build up of dust and debris while operating. 

Accessories must be removed prior to fitting the dust collection 

accessory.

On / Off Switch

Fitting the Dust Collection Accessory

Variable Speed

For various applications, you will need to select the appropriate 

speed for the task.

1.   Turn multi function tool on.

2.   Scroll through variable 

speed dial to desired speed 

setting.

Note:

 

The higher the number on the variable speed dial the 

faster the oscillation frequency of the multi function tool.

CAUTION:

 

THE POWER SUPPLY FOR THIS PRODUCT 

SHOULD BE PROTECTED BY A RESIDUAL CURRENT 

DEVICE (RATED AT 30mA OR LESS).

Summary of Contents for MFR-2200U

Page 1: ...d by a failure to follow the assembly instructions or due to incorrect installation a failure to follow the operating instructions for example connecting it to an incorrect mains voltage or current type or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance Damage to the device caused by abuse...

Page 2: ...SSORIES 1 ASSEMBLY Accessory Fitment 1 Place accessory over the drive spindle and position to suit angle needed for application Note Ensure the accessory is sitting flat on spindle and locking pins 2 Place flat side of accessory fitting washer on the accessory then insert locking bolt 3 Tighten locking bolt with hex key 1 Loosen locking bolt with hex key 2 Remove bolt and accessory Accessory Remov...

Page 3: ...n adaptor can be fitted to your multi function tool to reduce the build up of dust and debris while operating Accessories must be removed prior to fitting the dust collection accessory On Off Switch Fitting the Dust Collection Accessory Variable Speed For various applications you will need to select the appropriate speed for the task 1 Turn multi function tool on 2 Scroll through variable speed di...

Page 4: ...securely held down 3 Use slight pendulum motion when plunge cutting Note Ensure blades are not blunt or damaged in any way before commencing application Grout Removal Disc 1 Turn the multi function tool on and select speed Triangular Rasp 1 Turn multi function tool on and select appropriate speed 2 Place the multi function tool flat on the workpiece This accessory is suitable when sanding material...

Page 5: ...will not be responsible for any damage or injuries caused by the repair of the multi function tool by an unauthorised person or by mishandling of the multi function tool Sparking visible through the housing air vents A small amount of sparking may be visible through the housing vents This is normal and does not indicate a problem Excessive sparking visible through the housing air vents and or the ...

Page 6: ...ry pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This en...

Page 7: ...sumables Grinding sanding paper Missing parts Not necessarily included in the scope of delivery In the effect of defects or faults please register the problem on the internet at www isc gmbh info Plea se ensure that you provide a precise description of the problem and answer the following questions in all cases Did the equipment work at all or was it defective from the beginning Did you notice anyt...

Page 8: ... can cause damage to hea ring Total vibration values vector sum of three direc tions determined in accordance with EN 60745 Handle Vibration emission value ah 8 081 m s2 K uncertainty 1 5 m s2 The specified vibration value was established in accordance with a standardized testing method It may change according to how the electric equip ment is used and may exceed the specified value in exceptional...

Reviews: