MAINTENANCE

TROUBLESHOOTING

OPERATION

DESCRIPTION OF SYMBOLS

•  Keep the ventilation vents of the multi function tool clean at all times,  

if possible, prevent foreign matter from entering the vents.

•  After each use, blow air through the multi function tool housing to ensure it is 

free from all dust particles which may build up. Build up of dust particles may 

cause the tool to overheat and fail.

•  If the enclosure of the multi function tool requires cleaning, do not use 

solvents but a moist soft cloth only. Never let any liquid get inside the multi 

function tool; never immerse any part of the multi function tool into a liquid.

Carbon Brushes

When the carbon brushes wear out, the multi function tool will spark and/

or stop. Discontinue use as soon as this happens. They should be replaced 

prior to recommencing use of the multi function tool. 

Carbon brushes are a wearing component of the 

tool and therefore are not covered under warranty. 

Continuing to use the multi function tool when carbon 

brushes need to be replaced may cause permanent 

damage. Carbon brushes will wear out after many 

uses but when the carbon brushes need to be 

replaced, take the multi function tool to an electrician 

or a power tool repairer for a quick and low cost replacement. Always replace 

both carbon brushes at the same time.

Note: Ozito Industries will not be responsible for any damage or injuries caused 

by the repair of the multi function tool by an unauthorised person  

or by mishandling of the multi function tool.

Sparking visible through the housing air vents

A small amount of sparking may be visible through the housing vents.  

This is normal and does not indicate a problem.

Excessive sparking visible through the housing air vents 

and/or the multi function tool failing to operate

May indicate the carbon brushes have worn out and need to be 

replaced. Carbon brushes should only be replaced by a qualified 

electrician or power tool repairer.

WARNING:

 

BEFORE CARRYING OUT ANY MAINTENANCE 

PROCEDURES, ENSURE THE TOOL IS SWITCHED OFF 

AND DISCONNECTED FROM THE POWER SUPPLY.

  

V

 

    

Volts

    

Hz

 

    

Hertz

  

~

 

    

Alternating current

  

W

 

    

Watts

/min

      

Revolutions or 

 

    reciprocation per minute

 

    

Double insulated 

 

 

                  

n

o       

No load speed

Warning

Read instruction manual

5.  SCRAPING

1.   Turn multi function 

tool on and select 

appropriate speed.

2.   Place multi function tool on the workpiece at an angle of 

approximately 10-15

°

.

3.   Allow the scraper to do the work; do not apply heavy pressure 

to the multi function tool. This may cause the multi function 

tool to overload or cut into the surface of the workpiece.

10 - 15º

SPARE PARTS

Spare parts can be ordered from the Special Orders Desk 

at your local Bunnings Warehouse or Homebase store.
For further information, or any parts visit 
www.ozito-diy.co.uk or contact Ozito Customer Service:
Great Britain: 0151 294 4488
Ireland: 1850 882711
E-mail: [email protected]

Summary of Contents for MFR-2200U

Page 1: ...d by a failure to follow the assembly instructions or due to incorrect installation a failure to follow the operating instructions for example connecting it to an incorrect mains voltage or current type or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance Damage to the device caused by abuse...

Page 2: ...SSORIES 1 ASSEMBLY Accessory Fitment 1 Place accessory over the drive spindle and position to suit angle needed for application Note Ensure the accessory is sitting flat on spindle and locking pins 2 Place flat side of accessory fitting washer on the accessory then insert locking bolt 3 Tighten locking bolt with hex key 1 Loosen locking bolt with hex key 2 Remove bolt and accessory Accessory Remov...

Page 3: ...n adaptor can be fitted to your multi function tool to reduce the build up of dust and debris while operating Accessories must be removed prior to fitting the dust collection accessory On Off Switch Fitting the Dust Collection Accessory Variable Speed For various applications you will need to select the appropriate speed for the task 1 Turn multi function tool on 2 Scroll through variable speed di...

Page 4: ...securely held down 3 Use slight pendulum motion when plunge cutting Note Ensure blades are not blunt or damaged in any way before commencing application Grout Removal Disc 1 Turn the multi function tool on and select speed Triangular Rasp 1 Turn multi function tool on and select appropriate speed 2 Place the multi function tool flat on the workpiece This accessory is suitable when sanding material...

Page 5: ...will not be responsible for any damage or injuries caused by the repair of the multi function tool by an unauthorised person or by mishandling of the multi function tool Sparking visible through the housing air vents A small amount of sparking may be visible through the housing vents This is normal and does not indicate a problem Excessive sparking visible through the housing air vents and or the ...

Page 6: ...ry pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This en...

Page 7: ...sumables Grinding sanding paper Missing parts Not necessarily included in the scope of delivery In the effect of defects or faults please register the problem on the internet at www isc gmbh info Plea se ensure that you provide a precise description of the problem and answer the following questions in all cases Did the equipment work at all or was it defective from the beginning Did you notice anyt...

Page 8: ... can cause damage to hea ring Total vibration values vector sum of three direc tions determined in accordance with EN 60745 Handle Vibration emission value ah 8 081 m s2 K uncertainty 1 5 m s2 The specified vibration value was established in accordance with a standardized testing method It may change according to how the electric equip ment is used and may exceed the specified value in exceptional...

Reviews: