The DC output on this generator has a rated voltage of 12V with a rated 

current of 8.3A.

DC Applications

12Volt DC Outlet

This is suitable for charging most lead acid type car batteries.
Before charging, remove the battery from the vehicle. The battery 

MUST be totally isolated from any other circuitry.
1.   Connect the positive (+, RED) 

charging cord to the positive 

battery terminal. Connect the 

negative (-, BLACK) charging cord 

to the negative battery terminal. Do 

not reverse the charging cables, or 

serious damage to the generator 

and/or the battery may occur.

ON

I

0

IGP 2500

AC 240V

DISPLAY METER

RATED POWER   2.2kW
MAX. POWER     2.5kW

OFF

DC PROTECTOR

+

 DC 2V 3.3A

-

2.   Start the generator as described in 

“Starting the engine”

 section.

3.   Connect the DC cable to the 12Volt 

DC outlet. The battery will begin 

charging.

4.   When disconnecting, remove the 

plug from the generator before 

unclipping the clamps on the 

battery.

Note: 

Do not attempt to charge lithium ion, NiCad or NiMH batteries. 

The charging outlet is only intended for Lead Acid batteries.

WARNING!

 

THE BATTERY GIVES OFF EXPLOSIVE 

GASES; KEEP SPARKS, FLAMES AND CIGARETTES 

AWAY. PROVIDE ADEQUATE VENTILATION WHEN 

CHARGING.

WARNING!

 

THE BATTERY CONTAINS SULPHURIC 

ACID (ELECTROLYTE). CONTACT WITH SKIN OR EYES 

MAY CAUSE SEVERE BURNS. WEAR PROTECTIVE 

EQUIPMENT.

WARNING!

 

BATTERIES LEFT UNATTENDED CAN 

POTENTIALLY EXPLODE, RESULTING IN SERIOUS  

INJURY.

WARNING!

 

THIS GENERATOR IS NOT SUITABLE FOR 

PERMANENT HOUSEHOLD INSTALLATION AND/OR 

APPLICATIONS.

ON

I

0

IGP 2500

AC 240V

DISPLAY METER

RATED POWER   2.2kW
MAX. POWER     2.5kW

OFF

DC PROTECTOR

+

 DC 2V 3.3A

-

Note: 

DC receptacle can be used while the 

AC power is in use. If you use both at the 

same time, be sure not to exceed the total 

power for AC and DC. An overloaded DC 

circuit will trip the DC circuit breaker. If this 

happens, disconnect the DC load before 

pushing in the ‘DC Overload Reset’ button to 

resume operation.

When reconnecting appliances, reduce the load which previously 

overloaded the generator.

AC Applications

Check the total rating of the appliance 

to be connected and ensure the rating 

of the appliance/s does not exceed the 

rating of the generator.

1.   Start the engine and make sure 

the output indicator LED (green) 

illuminates. (see 

“Starting the 

engine”)

2.   Confirm that the equipment to be used and the AC power switch 

on the control panel is switched off, and insert the plug of the 

equipment to be used into an AC socket.

3.   Switch the AC power switch on the control panel up into the on 

position and then you can start using the equipment.

Note: 

If the connected appliance does not operate, refer to 

“Overload 

Indicator”

 section.

Note: 

Please be aware that the starting current of certain equipment 

may be higher than it is rated.

Appliance

Running Wattage

Start-up Wattage

Light

70W

70W

Airless Sprayer

650W

1300W

Refrigerator

700W

2000W

Water Pump

800W

2000W

Air Compressor (1HP)

1100W

4000W

Circular Saw

1200W

2100W

Heater

2000W

2000W

Mitre Saw

2100W

3200W

Electric Stove

2400W

2400W

Overloading (Inrush Current)

You may find that even though the appliance you wish to connect to the generator 

is below the rated power, the generator overloads.
Some appliances require a higher power than noted on the appliance for start up; 

this is called inrush current. Some examples are listed below.

*Table details are approximate. Always check your appliance for the accurate wattage.

Summary of Contents for IGP-2500

Page 1: ...sassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE...

Page 2: ...ss however only the oil plug towards the front features a dipstick for checking the level Checking the Oil 2 Remove the dipstick and wipe with a clean rag Check the oil level by inserting the dipstick...

Page 3: ...FORE STARTING THE ENGINE WARNING KEEPAWAY FROM CIGARETTES SMOKEAND SPARKS WHEN REFUELLING THE GENERATOR ALWAYS REFUEL IN A WELL VENTILATED LOCATION Before starting the engine disconnect all appliances...

Page 4: ...ator LED red may shorten the service life of the generator Stop the engine if the overload indicator light red switches ON and investigate the overload source Overload Indicator LED Low Oil Indicator...

Page 5: ...3 3A Note DC receptacle can be used while the AC power is in use If you use both at the same time be sure not to exceed the total power for AC and DC An overloaded DC circuit will trip the DC circuit...

Page 6: ...KE SURE TO TURN THE ENGINE SWITCH AND FUEL LEVER ARE OFF BEFORE DRAINING 1 Using a spanner remove the oil drain screw 2 Tilt the generator and spill out the oil into a suitable container 3 Refit the o...

Page 7: ...fuel filter can be found under the fuel cut off tap TROUBLESHOOTING Circuit Breaker Trips During Use If the circuit breaker trips during use it usually indicates faulty electrical equipment or cords F...

Page 8: ...W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual HOT Engine may continue to rotate after machine is switched off Frame Chassis 4...

Reviews: