background image

1

ONLINE MANUAL

Scan this QR Code with your 

mobile device to take you to 

the online manual.

ON

I

0

IGP 2500

AC 240V

DISPLAY METER

RATED POWER   2.2kW
MAX. POWER     2.5kW

OFF

DC PROTECTOR

+

 DC 2V 3.3A

-

1.   Frame
2.   Choke
3.   Recoil Starter
4.   Fuel Gauge
5.   Fuel Tank Cap
6.   Control Panel
7.   Oil Dipstick
8.   Oil Fill Port
9.   Transport Handle
10.   Air  Filter

11.   Fuel  Tap

12  Engine On/Off Switch 

13.  Display Meter
14.  AC Socket x 2
15.  AC Power Switch
16.  Status LEDs
17.  DC Overload Reset
18.  12Volt DC Outlet
19.   Grounding  Terminal

INVERTER GENERATOR

KNOW YOUR PRODUCT

1.  LUBRICATION

SETUP & PREPARATION

1

2

3

4

5

6

9

7

15

13

14

8

10 11

The generator is shipped without oil and must be filled before starting. 

Oil sump capacity is 600ml. Refer to below instructions for details.

Note:

 The generator has 2 oil filler holes for easier access, however 

only the oil plug towards the front features a dipstick for checking the 

level.

Checking the Oil

2.   Remove the dipstick, and 

wipe with a clean rag. Check 

the oil level by inserting 

the dipstick in the filler hole 

without screwing it in and 

then removing it again.

3.   If the oil level is below the 

end of the dipstick, using 

the oil filler bottle, refill until 

it registers on the halfway 

mark of the dipstick. Use 

premium quality 4-stroke 

engine oil. Recommended 

SAE30 or 15W40 for 

most climate conditions in 

Australia.

Upper 
level 
allowed

12

20

21

TOOLS & ACCESSORIES

22

23

24

20.  Oil Filler Bottle
21.  Battery Charging Cable
22.  Spark Plug Wrench

23.  Spare Spark Plug
24. Generator Oil

Upper 
level 
allowed

Note: 

The Oil Alert LED will automatically illuminate before the oil level 

falls below the safe limit. However, to avoid the inconvenience, it is still 

advisable to visually inspect the oil level regularly.

1.   Be sure to check that the generator is on a level surface with the 

engine stopped.

16 17

19

18 

Summary of Contents for IGP-2500

Page 1: ...sassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE...

Page 2: ...ss however only the oil plug towards the front features a dipstick for checking the level Checking the Oil 2 Remove the dipstick and wipe with a clean rag Check the oil level by inserting the dipstick...

Page 3: ...FORE STARTING THE ENGINE WARNING KEEPAWAY FROM CIGARETTES SMOKEAND SPARKS WHEN REFUELLING THE GENERATOR ALWAYS REFUEL IN A WELL VENTILATED LOCATION Before starting the engine disconnect all appliances...

Page 4: ...ator LED red may shorten the service life of the generator Stop the engine if the overload indicator light red switches ON and investigate the overload source Overload Indicator LED Low Oil Indicator...

Page 5: ...3 3A Note DC receptacle can be used while the AC power is in use If you use both at the same time be sure not to exceed the total power for AC and DC An overloaded DC circuit will trip the DC circuit...

Page 6: ...KE SURE TO TURN THE ENGINE SWITCH AND FUEL LEVER ARE OFF BEFORE DRAINING 1 Using a spanner remove the oil drain screw 2 Tilt the generator and spill out the oil into a suitable container 3 Refit the o...

Page 7: ...fuel filter can be found under the fuel cut off tap TROUBLESHOOTING Circuit Breaker Trips During Use If the circuit breaker trips during use it usually indicates faulty electrical equipment or cords F...

Page 8: ...W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual HOT Engine may continue to rotate after machine is switched off Frame Chassis 4...

Reviews: