1
2. FUEL
3. STARTING & STOPPING
OPERATION
Refuelling the Generator
Fuel Consumption
Preparing to Start
2. Set the engine switch to
ON.
1. Set the fuel tap to the “ON”
position as shown.
3. Adjust the choke to suit the current
conditions.
COLD START:
If the weather is cold,
push the choke all the way to the left
into the “ON” position.
WARM START:
If the weather is warm
or the generator has recently been
used, push the choke all the way to
the right into the “OFF” position.
OFF
ON
1. Switch off engine by
moving the engine switch
to the OFF position.
2. Remove the fuel cap by
rotating in a anti-clockwise
direction.
3. Add fuel to the tank (91 RON
Unleaded Petrol). Do not
overfill the fuel tank, check
the fuel gauge on the fuel
tank. Do not use ethanol
blended fuels. Fuel tank
capacity is 5L.
E
F
4. After refuelling, make sure the fuel cap is closed properly and
securely.
WARNING!
BE CAREFUL NOT TO SPILL FUEL WHEN
REFUELLING. SPILLED FUEL OR FUEL VAPOUR MAY
IGNITE. IF ANY FUEL IS SPILLED, MAKE SURE THE AREA
IS DRY BEFORE STARTING THE ENGINE.
WARNING!
KEEP AWAY FROM CIGARETTES, SMOKE AND
SPARKS WHEN REFUELLING THE GENERATOR. ALWAYS
REFUEL IN A WELL-VENTILATED LOCATION.
Before starting the engine, disconnect all appliances from the
generator.
OFF
ON
CHOKE LEVER
Starting the Engine
Before starting the engine, disconnect all appliances from the
generator.
1. Follow steps 1 to 3 in the
“Preparing to Start”
section above.
2. Hold the generator steady
with one hand. With the
other hand, pull slightly on
the recoil starter until you
feel resistance and then
pull hard and swiftly. Do
not let the recoil starter
retract by itself, guide it
back by hand.
3. Once started push the choke all the way to the right into the “OFF”
position.
Note:
You may need to pull on the recoil starter a few times until the
generator starts.
WARNING!
PETROL IS VERY FLAMMABLE. DO NOT
SMOKE OR CAUSE ANY SPARKS OR FLAMES NEAR
FUEL. MAKE SURE THAT YOU STOP THE ENGINE
AND ALLOW IT TO COOL BEFORE REFUELLING THE
GENERATOR. SELECT AN OPEN OUTDOOR AREA FOR
FUELLING AND MOVE AT LEAST 3M AWAY FROM THE
FUELLING POINT BEFORE STARTING THE ENGINE.
Load
Fuel Consumption
Run Time (full tank)
2200W (full load)
1500mL/h
3 hours
1100W (half load)
1026mL/h
4.5 hours