DESCRIPTION OF SYMBOLS

Cleaning

1.  We recommend that you clean the appliance immediately after 

you use it.

2.  Keep the safety devices free of dirt and dust as much as 

possible. Wipe the equipment with a clean cloth.

3.  Clean the appliance regularly with a damp cloth and some soft 

soap. Do not use cleaning agents or solvents; these may be 
aggressive to the plastic parts in the appliance. Ensure that no 
water can get into the interior of the appliance.

4.  You must disconnect the hose and any spraying tools from the 

compressor before cleaning. Do not clean the compressor with 
water, solvents or the like.

Storage

Switch off the compressor, pull the mains plug out of the socket, 
and ventilate the appliance and all connected pneumatic tools. 
Drain the pressure tank.

Make sure that it is secured in such a way that it cannot be started 
up again by any unauthorised person.

Store the tool in a dry location which is not accessible to 
unauthorised persons.

Supply Cords

If replacement of the supply cord is necessary, this has to be done 
by a certified electrician in order to avoid a safety hazard.

Note: 

Ozito Industries will not be responsible for any damage or 

injuries caused by the repair of the tool by an unauthorised person 
or by mishandling of the tool.

WARNING! 

BEFORE CLEANING THE APPLIANCE OR 

CARRYING OUT ANY MAINTENANCE PROCEDURE, 
MAKE SURE THAT IT IS DISCONNECTED FROM THE 
POWER SUPPLY TO PREVENT ACCIDENTAL STARTING.

Sound Power Level

Wear hearing protection

Warning

Regulatory Compliance Mark
(RCM)

V

Volts

Hz

W

Hertz

~

n

0

/min

Alternating Current

Watts

No load speed

Revolutions or reciprocations 
per minute

Read Instruction Manual

Beware of electrical voltage

Beware of hot parts.

Pressure rating

Do not open the outlet before 
the air hose is attached

bar

L

Litres

No protection against ingress
from water

lP20

Warning! The equipment is
remote-controlled and may 
start-up without warning.

Power tools that are no longer usable should not 
be disposed of with household waste but in an 
environmentally friendly way. Please recycle where 
facilities exist. Check with your local council authority for 
recycling advice.

Recycling packaging reduces the need for landfill and raw 
materials. Reuse of recycled material decreases pollution 
in the environment. Please recycle packaging where 
facilities exist. Check with your local council authority for 
recycling advice.

CARING FOR THE ENVIRONMENT

SPARE PARTS

Spare parts can be ordered from the Special Orders Desk at your 
local Bunnings Warehouse. 

For further information, or any parts not listed here, visit  

www.ozito.com.au or contact Ozito Customer Service: 

Australia 1800 069 486 

New Zealand 0508 069 486 

E-mail: [email protected]

Summary of Contents for ACP-4025

Page 1: ... If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 40L Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts 2 x Support Feet 2 x Small Bolts 4 x Washers 2 x Spring Washers 2 x Nuts 1021 IN ORDER TO MAK...

Page 2: ...ks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas w...

Page 3: ...3 Check that the fitting is secure by tugging gently on the connector If the hose detaches repeat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the air compressor 2 Repeat the same procedure with the air tool and air hose 0 25 50 75 10 0 125 1...

Page 4: ...f pressure If you are unsure use an attached blow gun to release some of the pressure until the tank pressure gauge drops below 6bar If the motor does not automatically start up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes before restarting WARNING ALLOW THE AIR CO...

Page 5: ...s attached and allow any liquid to drain from the tank 4 Turn off the compressor and close the drain valve The compressor is now ready for use 5 Attach the desired tool to one end of an air hose and the air hose to an outlet depending on the tool or application 6 Turn the compressor back on and adjust the regulated pressure to the desired level once the pump has shut off and the compressor has rea...

Page 6: ... does not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insufficient supply power Reduce length of extension lead Outside temperature is too low Never operate with an outside temperature of below 5 C Motor is overheated Allow the motor to cool down If neces...

Page 7: ...g of the tool WARNING BEFORE CLEANING THE APPLIANCE OR CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING Sound Power Level Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual Beware ...

Page 8: ...t including safety goggles or shield ear protection breathing or respirator mask and protective clothing Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a ...