3. CONTROLS

OPERATION

Adjusting The Output Pressure

The output pressure of the regulated pressure outlet can be 
adjusted to suit the air tool connected and the task at hand.

1.  To do so, first decrease the 

pressure to 0psi by turning 
the pressure regulator anti-
clockwise.

2.  Then turn the pressure 

regulator clockwise until the 
desired pressure is shown 
on the regulated pressure 
gauge.

WARNING! 

DO NOT ATTEMPT TO ADJUST/MODIFY 

THE SAFETY VALVE IN ANY WAY. THE SAFETY VALVE 
INSTALLED ON THIS AIR COMPRESSOR IS DESIGNED 
TO AUTOMATICALLY RELEASE PRESSURE IN CASE OF 
EXCESS PRESSURE BUILD UP IN THE TANK.

Switching The Compressor On/Off

1.  To switch the compressor 

on, twist and pull the on/
off switch to the ‘I’ position. 
Allow the motor to run and 
the tank to fill up.

Note:

 

The compressor will automatically cut off when the tank 

pressure reaches 8bar and will automatically start up again when 
the tank pressure drops to 6bar.

2.  To switch the compressor off, twist and press the on/off switch 

to the ‘0’ position.

Thermal Overload Protection

This Air Compressor is fitted with thermal protection and will shut 
off to protect the compressor from overheating.

The compressor may also have shut off due to reaching max. 
cut off pressure. If you are unsure, use an attached blow gun to 
release some of the pressure until the tank pressure gauge drops 
below 6bar. If the motor does not automatically start up, the unit 
has overloaded and the thermal protection has activated.

If the thermal protection activates, switch off the compressor and 
allow the compressor to cool down for 15 minutes before 
restarting. 

WARNING! 

ALLOW THE AIR COMPRESSOR TO COOL 

BEFORE ATTEMPTING ANY MAINTENANCE.

WARNING! 

DO NOT CONTINUE USE OF THE UNIT 

IF THE THERMAL PROTECTION ACTIVATES AGAIN 
IMMEDIATELY AFTER THE RESET.

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

2.0HP 40L 

ON

OFF

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

WARNING! 

THE AIR COMPRESSOR MUST BE USED 

WITH A RESIDUAL CURRENT DEVICE WITH A RATED 
RESIDUAL CURRENT OF 30MA OR LESS.

WARNING! 

DO NOT LEAVE THE AIR COMPRESSOR 

UNATTENDED WHILE THE ON/OFF SWITCH IS IN THE 
‘ON’ POSITION.

Summary of Contents for ACP-4025

Page 1: ... If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 40L Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts 2 x Support Feet 2 x Small Bolts 4 x Washers 2 x Spring Washers 2 x Nuts 1021 IN ORDER TO MAK...

Page 2: ...ks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas w...

Page 3: ...3 Check that the fitting is secure by tugging gently on the connector If the hose detaches repeat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the air compressor 2 Repeat the same procedure with the air tool and air hose 0 25 50 75 10 0 125 1...

Page 4: ...f pressure If you are unsure use an attached blow gun to release some of the pressure until the tank pressure gauge drops below 6bar If the motor does not automatically start up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes before restarting WARNING ALLOW THE AIR CO...

Page 5: ...s attached and allow any liquid to drain from the tank 4 Turn off the compressor and close the drain valve The compressor is now ready for use 5 Attach the desired tool to one end of an air hose and the air hose to an outlet depending on the tool or application 6 Turn the compressor back on and adjust the regulated pressure to the desired level once the pump has shut off and the compressor has rea...

Page 6: ... does not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insufficient supply power Reduce length of extension lead Outside temperature is too low Never operate with an outside temperature of below 5 C Motor is overheated Allow the motor to cool down If neces...

Page 7: ...g of the tool WARNING BEFORE CLEANING THE APPLIANCE OR CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING Sound Power Level Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual Beware ...

Page 8: ...t including safety goggles or shield ear protection breathing or respirator mask and protective clothing Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a ...

Reviews: