Attaching The Support Foot

1.  Place the supporting foot and then a small 

washer onto the small bolt. Thread this 
through the hole in the foot bracket.

2.  Thread the other small washer and then 

the spring washer onto the bolt. Secure the 
assembly with the small nut.

Attaching The Wheels

1.  Place the large bolt through 

the wheel and a large 
washer. Then slide this 
through the hole in the 
wheel bracket. Place a large 
washer then a spring washer 
onto the bolt and secure this 
with a large nut.

2.  Repeat step 1 to fit the second wheel on the opposite side of the 

tank. 

Connecting An Air Hose to the Compressor

1.   Pull back the sleeve on the 

regulated pressure outlet of 
the compressor and insert 
the male Nitto end of the air 
hose..

2.  Release the sleeve; the Nitto 

coupling should click into 
place.

3.  Check that the fitting is secure by tugging gently on the 

connector. If the hose detaches, repeat steps 2 & 3, pushing the 
Nitto connector firmly into the outlet.

Disconnecting Air Tools

1.  To remove an air tool from the unit, retract the sleeve on the 

female Nitto fitting and disconnect the air hose from the air 
compressor.

2.  Repeat the same procedure 

with the air tool and air 
hose.

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²
(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

WARNING! 

ENSURE YOU HAVE A FIRM GRIP ON THE 

AIR HOSE WHEN CONNECTING/DISCONNECTING IT 
FROM THE AIR COMPRESSOR, AS PRESSURISED AIR 
IN THE TANK MAY CAUSE IT TO WHIP AROUND AND 
INFLICT INJURY OR DAMAGE.

Summary of Contents for ACP-4025

Page 1: ... If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 40L Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts 2 x Support Feet 2 x Small Bolts 4 x Washers 2 x Spring Washers 2 x Nuts 1021 IN ORDER TO MAK...

Page 2: ...ks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas w...

Page 3: ...3 Check that the fitting is secure by tugging gently on the connector If the hose detaches repeat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the air compressor 2 Repeat the same procedure with the air tool and air hose 0 25 50 75 10 0 125 1...

Page 4: ...f pressure If you are unsure use an attached blow gun to release some of the pressure until the tank pressure gauge drops below 6bar If the motor does not automatically start up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes before restarting WARNING ALLOW THE AIR CO...

Page 5: ...s attached and allow any liquid to drain from the tank 4 Turn off the compressor and close the drain valve The compressor is now ready for use 5 Attach the desired tool to one end of an air hose and the air hose to an outlet depending on the tool or application 6 Turn the compressor back on and adjust the regulated pressure to the desired level once the pump has shut off and the compressor has rea...

Page 6: ... does not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insufficient supply power Reduce length of extension lead Outside temperature is too low Never operate with an outside temperature of below 5 C Motor is overheated Allow the motor to cool down If neces...

Page 7: ...g of the tool WARNING BEFORE CLEANING THE APPLIANCE OR CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING Sound Power Level Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual Beware ...

Page 8: ...t including safety goggles or shield ear protection breathing or respirator mask and protective clothing Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a ...