SPECIFICATIONS

Input: 

230–240V ~ 50Hz

Motor: 

1500W S3:25%

No Load Speed: 

4,000/min

Tank Volume: 

24 litres

Max. Pressure: 

10 bar (145psi)

Max. Air Delivery:  173 l/min
                 @ 4 Bar:  107 l/min
                 @ 7 Bar:  76 l/min
IP Rating: 

IP20

Weight:  

16.2kg

ACP-2419

WHAT’S IN THE BOX

ozito.com.au

Compact Air Compressor

Wheels x 2, Hub Cap x 2, 

Axle x 1, Caps x 2

Support Foot

Summary of Contents for ACP-2419

Page 1: ...or 1500W S3 25 No Load Speed 4 000 min Tank Volume 24 litres Max Pressure 10 bar 145psi Max Air Delivery 173 l min 4 Bar 107 l min 7 Bar 76 l min IP Rating IP20 Weight 16 2kg ACP 2419 WHAT S IN THE BO...

Page 2: ...sor may only be used in suitable rooms with good ventilation and an ambient temperature from 5 C to 40 C There must be no dust acids vapours explosive gases or inflammable gases in the room The compre...

Page 3: ...f switch to position I On 3 To switch the compressor Off move the On Off switch to position O Off Adjusting the pressure Once set up and On you can adjust the air pressure by turning the pressure regu...

Page 4: ...ll turn on again automatically to build up maintain pressure Checking the safety valve 1 Check that the safety valve is in working order every use Turn compressor on until the switch off pressure 10 b...

Page 5: ...use of the overheating The compressor starts but there is no pressure 1 Leak in the non return valve 1 Replace the non return valve 2 The seals are damaged 2 Check the seals and have any damaged seals...

Page 6: ...SURIZE THE TANK BEFORE CARRYING OUT ANY CLEANING AND MAINTENANCE WORK Check the tank for signs of rust and damage each time before using Do not use the compressor with a damaged or rusty tank Note Thi...

Page 7: ...tomer Service Australia 1800 069 486 New Zealand 0508 069 486 E mail enquires ozito com au SPARE PARTS V Volts Hz Hertz Alternating current W Watts min Revolutions or reciprocation per minute no No lo...

Page 8: ...lowing should always be followed to reduce risk of fire electric shock personal injury and material damage Read the whole manual carefully and make sure you know how to switch the tool off in an emerg...

Page 9: ...ay Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL...

Reviews: