background image

                                                                                      -

6-

                                                                                   

CHARGING STAGES 

 

 

 

Note:

 The Charger automatically switches off after 24 hours if the Bulk charge cycle is not completed. 

 

CHARGER SPECIFICATIONS 

 
1.  Input: 220~260Vac; 50Hz;  
2.    Charging starting conditions: Battery is not less than 1.5V 
3.    Rated output: 13.5V at 2/4/8A selectable on OC-SW121080,   

13.5V at 2/8/16A selectable on OC-SW121160, 
13.5V at 2/10/21A selectable on OC-SW121210, 

4.    Type of Lead-acid Battery: Gel/Conventional Sealed,WET/Calcium

 

5.    Charging output voltage (Absorption): 14.1/14.4/14.7V at Gel/Sealed,WET/Calcium 
6.    Charging output voltage (Automatic Equalisation): 16.2V only for Calcium battery 
7.    Float output voltage: 13.8V for Gel/Sealed,WET/Calcium 
8.    Manual Equalisation voltage: 15.5V for Conventional Seal and WET batteries. 
8.    Operating Environmental: 0~40 degC, 90% RH maximum; non-Condensing 
9.    Net Weight: 860g approx (OC-SW121080); 1.3Kg approx (OC-SW121160 & OC-SW121210) 
10. Dimension: L192 x W95 x H55mm (OC-SW121080); L230 x W132 x H76mm (OC-SW121160 & OC-SW121210)

 

 

TROUBLE SHOOTING 

 

Problems 

Indication 

Possible causes 

Suggest solution 

Charger does 
not work 

Indicator lights are not 
on 

- No AC power 

- Check AC connections and make       
  sure Power Point is switched ON 
 

 
Charger has 
no DC output 

 
Fault LED is Flashing. 

- Output is short circuited 
 
 
- Output cables are not connected to the 

battery. 

- Output Reverse polarity connection 

- Check DC connection between charger 

and battery and make sure they are not 
short circuiting. 

- Check that the crocodile clips haven’t 

fallen off the battery. 

- Check that the crocodile clips / ring 

terminals are connected to the correct 
polarity. 

 
No Charging 
Current 

 
Fault LED is ON 

- Battery is severely sulphated 
- Battery has a damaged cell 
 
- Charger overhead protection mode 

- Check the Battery condition, age etc. 
- If battery cannot be rejuvenated it must 

be replaced. 

- Move battery & Charger to cooler 

environment 

Long charging 
time, Full light 
does not come 
on 

 
Fault LED is ON 

- Wrong battery type selected 
- Battery capacity too large 
- Battery is defective 
- 6 hours soft start timer reached 
- 24 hours bulk charge timer reached 

- Check the charging rate and battery type 

selection matches the battery. 

- Battery cannot be charged and must   
 be replaced. 

Abnormal LED 
indication 

 
ALL LED’s Flash 

- Poor connection from Charger to           
 Battery 

- Check for a loose battery terminal   
 connection. 
- Check the output wires crocodile clips   
  for loose / damaged connection.   

Battery will not 
hold charge once 
Full 

 
Full LED ON 

- Battery has a damaged cell/s 
- Battery contains calcium content and     
  requires different battery type selection 

- Try Manual Equalisation Mode 
- Refer to Battery Manufacturer’s   
  Specifications and try Calcium Setting. 

 
 

Summary of Contents for OC-SW121080

Page 1: ...to a qualified person if a repair is required Keep the charger away from infants children and pets Switch off the mains power supply before connecting or disconnecting the unit to a Battery CAUTIONS R...

Page 2: ...Battery Full LED Green Indicates the Battery is fully charged 6 Charging Fault LED Display See trouble shooting for further details 7 Rejuvenation Stage LED Display Yellow Blinking LED Indicates the R...

Page 3: ...as the Automatic Equalisation feature pushes the charge voltage up to an equalising level of 16 2V 3 Connect the battery charger to the Mains power 240Vac a The Charger will automatically start when A...

Page 4: ...ull Float Battery is fully charged and is ready for use It will be maintained at a safe constant voltage Battery type selection GEL 13 8V Sealed WET 13 8V Calcium 13 8V Indicated by the Green Full LED...

Page 5: ...ption mode has finished Equalisation is indicated by the Absorption GREEN LED Flashing Note Equalisation Mode will not work if the Charger is in Full Mode The Button must be pressed during the chargin...

Page 6: ...ashing Output is short circuited Output cables are not connected to the battery Output Reverse polarity connection Check DC connection between charger and battery and make sure they are not short circ...

Page 7: ...and or OzCharge service centre concludes that while under normal use a product failure or malfunction occurred during the warranty period and was caused by a defect in material or workmanship see Excl...

Page 8: ...8 Specifications subject to change without notice Distributed by Zylux Distribution Pty Ltd website www ozcharge com au Rev 1 07...