background image

                                                                                      -

2-

                                                                                   

CONTROL AND INDICATORS 

 

 

 

1.  Charging Rate Selection Button 

Press to Select the Current Charge Rate. 

 

2.  Charging Current LED Display   

LED indicates the selected charging current 2A or 8A or 16A) (Example Model: OC- SW121160) 

 

3.  Battery Type Selection Button   

Press to select the Battery Type. (Calcium, Sealed/WET or GEL Lead Acid Batteries) 

 

4.  Battery Type LED Display 

LED indicates the selected Battery Type. 

 

5.  Charging Status LED Display 

Bulk LED – Blue: Indicates the charger is at a maximum charging rate.   
Absorption LED – Green: Indicates that the Battery is approaching full charge. 
Absorption LED – Blinking Green: Indicates automatic equalisation stage for Calcium Battery. 
Full LED – Green: Indicates the Battery is fully charged. 

 

6.  Charging Fault LED Display 

See trouble shooting for further details. 

 

7.  Rejuvenation Stage LED Display 

Yellow Blinking LED Indicates the Rejuvenation Charge. 

 

8.  Equalisation / Rejuvenation Selection Button 

Press this Button once to Select the Equalisation Charge Stage. 
Press and hold this Button for 3 seconds to start the Rejuvenation (De-Sulphation) Stage. 

 

9.  Equalisation Stage LED Display 

Red LED on indicates the Equalisation Charge Stage 

 
 

RECOMMENDED BATTERY CAPACITY 

 
The following minimum AH capacities are to be used as a general guide only. 
Some Batteries maybe able to handle a higher Charge Current;   
Check with the Battery Manufacturer when charging Batteries with small capacity. 

 
 
 
 

Charge Current 

2A 4A  8A  10A 16A 21A 

Battery Capacity 

6-40AH  12-80AH  18-120AH 30-200AH 45-300AH 60-400AH 

 
 
 

Summary of Contents for OC-SW121080

Page 1: ...to a qualified person if a repair is required Keep the charger away from infants children and pets Switch off the mains power supply before connecting or disconnecting the unit to a Battery CAUTIONS R...

Page 2: ...Battery Full LED Green Indicates the Battery is fully charged 6 Charging Fault LED Display See trouble shooting for further details 7 Rejuvenation Stage LED Display Yellow Blinking LED Indicates the R...

Page 3: ...as the Automatic Equalisation feature pushes the charge voltage up to an equalising level of 16 2V 3 Connect the battery charger to the Mains power 240Vac a The Charger will automatically start when A...

Page 4: ...ull Float Battery is fully charged and is ready for use It will be maintained at a safe constant voltage Battery type selection GEL 13 8V Sealed WET 13 8V Calcium 13 8V Indicated by the Green Full LED...

Page 5: ...ption mode has finished Equalisation is indicated by the Absorption GREEN LED Flashing Note Equalisation Mode will not work if the Charger is in Full Mode The Button must be pressed during the chargin...

Page 6: ...ashing Output is short circuited Output cables are not connected to the battery Output Reverse polarity connection Check DC connection between charger and battery and make sure they are not short circ...

Page 7: ...and or OzCharge service centre concludes that while under normal use a product failure or malfunction occurred during the warranty period and was caused by a defect in material or workmanship see Excl...

Page 8: ...8 Specifications subject to change without notice Distributed by Zylux Distribution Pty Ltd website www ozcharge com au Rev 1 07...