2-
CONTROL AND INDICATORS
1. Charging Rate Selection Button
Press to Select the Current Charge Rate.
2. Charging Current LED Display
LED indicates the selected charging current 2A or 8A or 16A) (Example Model: OC- SW121160)
3. Battery Type Selection Button
Press to select the Battery Type. (Calcium, Sealed/WET or GEL Lead Acid Batteries)
4. Battery Type LED Display
LED indicates the selected Battery Type.
5. Charging Status LED Display
Bulk LED – Blue: Indicates the charger is at a maximum charging rate.
Absorption LED – Green: Indicates that the Battery is approaching full charge.
Absorption LED – Blinking Green: Indicates automatic equalisation stage for Calcium Battery.
Full LED – Green: Indicates the Battery is fully charged.
6. Charging Fault LED Display
See trouble shooting for further details.
7. Rejuvenation Stage LED Display
Yellow Blinking LED Indicates the Rejuvenation Charge.
8. Equalisation / Rejuvenation Selection Button
Press this Button once to Select the Equalisation Charge Stage.
Press and hold this Button for 3 seconds to start the Rejuvenation (De-Sulphation) Stage.
9. Equalisation Stage LED Display
Red LED on indicates the Equalisation Charge Stage
RECOMMENDED BATTERY CAPACITY
The following minimum AH capacities are to be used as a general guide only.
Some Batteries maybe able to handle a higher Charge Current;
Check with the Battery Manufacturer when charging Batteries with small capacity.
Charge Current
2A 4A 8A 10A 16A 21A
Battery Capacity
6-40AH 12-80AH 18-120AH 30-200AH 45-300AH 60-400AH