8-
CHARGER SPECIFICATIONS
1.
Input:
230Vac nominal (216-264Vac); 50Hz;
2.
Charging starting conditions: Battery must be over 3.0V
3.
Rated output:
10Amps DC peak. 8Amps DC constant.
4.
Type of battery:
Lead-acid only (not Nickel-Cadmium, Lithium, etc). EG: Conventional/Calcium/AGM/Gel
5.
Charging output voltage:
14.1/14.4/14.7V programmable
for the “Absorption” stage
6.
Float output voltage:
13.7V for the finish trickle charge stage
7.
Equalise voltage:
15.5V current limited. Automatic for Calcium battery types
8.
Operating Environmental:
0~40 degC, 90% RH maximum; non-Condensing
9.
Net Weight (kg):
1.0 (approx.)
10.
Dimensions (mm):
140L x 145W x 55D
TROUBLE SHOOTING
Problems
Indication
Possible causes
Suggest solution
Charger does
not work
Indicator lights are not
on
No AC power
Internal fuse is blown due to poor AC
mains.
Check the AC plug connection at the base
of the main unit.
Have the generator checked.
Return the unit for service.
Charger has
no DC output
Battery Type green
LED is on.
No battery connection.
Battery is deeply-discharged.
Check the battery connection is secure.
Check the DC plug is fully connected
(vibration may have caused accidental
disconnection)
Check the battery voltage is over 3V.
No Charging
Current
Fault LED is blinking.
Fault LED is on solid.
Fault and green Bulk
LED are Flashing
Output is shorted or battery is connected in
reverse.
Over temperature shutdown
Soft Start mode has timed out
Check the DC cabling & master fuse.
Check the polarity of the battery
connection.
Check the charger is not covered and has
good ventilation. Allow to cool. Restart
the charger.
Battery is in extremely poor condition.
Turn off all loads. Restart the charger.
Run the Rejuvenate mode.
Replace battery if necessary.
2 YEAR MANUFACTURER WARRANTY
Zylux Distribution Pty. Ltd. (OzCharge) warrants to the Customer that this product is substantially free from defects in materials and
workmanship under normal use for a period of Two Years from the Date of Purchase.
Please ensure you keep a copy of your purchase on file as this will be required to validate your warranty.
Obtaining Warranty Service
Within the warranty period, the Customer must contact the authorised supplier / installer / retailer where the product was purchased or
alternatively you can contact the OzCharge service centre through one of the following methods:
Identify the serial number and proof of purchase first!
Hotline
:
Australia (03) 9482 2203
New Zealand (09) 527 7260
Website
:
www.ozcharge.com.au
www.ozcharge.co.nz
If the Authorised Supplier and / or OzCharge service centre concludes that while under normal use, a product failure or malfunction occurred
during the warranty period and was caused by a defect in material or workmanship (see Exclusions), the Customer will be asked to ship to
the nearest service point for
repair or replacement
, at our discretion. The product must be packaged appropriately for safe shipment. To
prove that the product is under warranty, the customer should enclose a copy of their receipt for proof of purchase. It is recommended that
returned products be sent by registered mail as Zylux Distribution Pty Ltd. (Ozcharge) accepts no responsibility / liability for goods lost or
damaged in transit. Return Shipping costs to be incurred by the Customer.
Exclusions
If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the
product does not exist or was caused by the Customer or any third persons misuse, physical abuse, water or lightning damage,
unauthorised attempts to open, repair or modify the product or improper installation, this will not be covered under this warranty.
This Warranty is void if:
1.
The product has been tampered with or repaired by an unauthorised person.
2.
The warranty seal is broken or altered.
3.
The warranty period has expired.
Specifications subject to change without notice.
Distributed by Zylux Distribution Pty. Ltd.
ABN: 66 101 378 009
© 2012
Rev_1.0