MAIN FEATURES 

• 

100% automatic smart battery charger & maintainer with reconditioning.

• 

The battery charger is easy to use and requires no technical experience.

• 

Fully microprocessor controlled with safety timers at every stage.

• 

Battery condition analysis.

• 

Senses whether battery is still connected in vehicle.

• 

Patented battery rejuvenation (reconditioning).

• 

Battery voltage retention analysis.

• 

Pulse charge for long term maintenance.

• 

Ultra lower power consumption (ECO Mode)

• 

Multi Stage:

1 - Qualification - Battery condition check
2 - Battery rejuvenation (recondition mode)
3 - Soft start charging
4 - Bulk charging
5 - Absorption charging
6 - Equalisation charging
7 - Battery analysis
8 - Float mode 
9 - Long term maintenance pulse charge 

• 

Automatic diagnosis and charge:

 On power up, the charger will automatically diagnose the 

battery condition and determine if the rejuvenation mode (reconditioning) or charge cycle is 
required.

• 

Patented battery rejuvenation technology:

  The charger has a unique and patented reju-

venation feature which uses high voltage equalising and peak pulse reconditioning to repair 
sulphated batteries. This feature is fully automatic and depends on the internal impedance of 
the battery. It also depends on whether the battery is still connected in the vehicle.

• 

Can be left on 24/7 to ensure your battery is always maintained and fully charged: 

The 

battery charger can be left unattended and left permanently connected all year round. The 
intelligent charger will monitor the battery voltage and will maintain it at peak performance 
with a special pulse charge during long term maintenance.

• 

Short circuit and reverse polarity protection.

• 

ECO Mode: 

Ultra low power consumption.

Summary of Contents for OC1204G

Page 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC1204G AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Page 2: ...d contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger Whe...

Page 3: ... diagnosis and charge On power up the charger will automatically diagnose the battery condition and determine if the rejuvenation mode reconditioning or charge cycle is required Patented battery rejuvenation technology The charger has a unique and patented reju venation feature which uses high voltage equalising and peak pulse reconditioning to repair sulphated batteries This feature is fully auto...

Page 4: ...hen connect the output leads to the correct polarity SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthechargerfrombeingdamagedif thepositiveandnegativecrocodileclipsorringterminalsaccidentlytoucheachotherwhilethe chargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power...

Page 5: ...r TECHNICAL SPECIFICATIONS Model Number OC1204G Output 4A 12V InputVoltage 100 240Vac 0 5A 65W Input Frequency 50 60Hz ChargeVoltage 14 4V EqualisingVoltage 14 6V FloatVoltage 13 6V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 182mm x 88mm x 48mm Weight 0 75kg Approvals CE UL cUL AS NZS EMC ...

Page 6: ...Ensure the battery is in a well ventilated area and the charger should be as far away from the battery as the cables permit STEP 2 Connecting the battery charger to your battery Simply plug the charger lead into the fly lead from your device ensuring the connector is lined up correctly and not stressed Note The plugs only fit one way and excess force is not advised STEP 3 Connecting the battery ch...

Page 7: ...ry voltage doesn t reach 11V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Uses the maximum charge output until the battery voltage reaches 14 4V If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the Red ...

Page 8: ...ies LED STATUS INDICATOR TABLE LED Status Description ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or ON during Absorption charging Bulk Blue Flash ON Fast Flash Rejuvenation Slow Flash Soft Start charging ON Bulk charging FaultLED Red ON Short circuit reverse polarity or...

Page 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Page 10: ...te The charger output is only present when connected to a battery No charging current Fault Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Batte...

Page 11: ...a copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Page 12: ...OC1204G Owner s Manual Rev 1 0 07 15 Specifications subject to change without notice SAAApproval No GMA 102826 EA 02 ...

Reviews: