11/09/2012
IMP-3003.100
III – USE
USE WITHOUT TIMER
- If the appliance is equipped with the timer option, check that the switch (
13
) is on the position ‘
no timer’
- Take the nose of the diffuser (
6
) out of the appliance by pressing on the button (5)
- Screw the bottle of product (
7
) taking care not to tighten too strong, to avoid damaging the joint in an irreversible way
- Replace the nose of the diffuser (
6
) on the device
- Connect the device to the electrical network 230/50 Hz with the power cable (
1
)
- Select with the button (
11
) the volume of the room to be treated (corresponds to duration of diffusion – check with table V)
- Press on the switch (
3
) to power on the NOCOSPRAY
- Steer the nose of diffuser (
6
) towards zones to be treated using the handle (
4
)
- Press on the "Start" button (
8
). A buzzer rings during 15 seconds leaving the time to go out of the room to be treated.
The device stops automatically.
- Wait at least for 30 minutes before going back into the room (refer to advised protocols)
- Press on the switch (
3
) to power off the device
If a problem appears, unplug the device and consult your retailer
USE WITH TIMER (OPTION)
To use the appliance with a timer, change the position of the « Switch for timer »
(13)
on position ‘
with timer
’.
On this position, the appliance will start directly when plugged in and the general switch
(3)
is on.
Turn the volume selector
(11)
at the maximum so that the stopping of the device is managed by the timer.
Notice: functioning time can not exceed the maximum volume selected.
IV
–
TRACEABILITY (option)
-
A Mini USB plug (12) allows to transfer the functioning historical data on a computer (see traceability software use manual).
-
In the case of use of a timer to start the device, the Nocospray must stop the device (the timer must not stop the device).
In the case the timer stops the device, this action will not be recorded in the historical data.
IV – MAINTENANCE
The device should be kept in a dry and clean place remote from any possible projections.
Change or clean if needed, the filtering foam
(10)
V
–
SELECTOR OPERATING (11)
1 liter of product = 1 hour of diffusion = 1000 m
3
treated (with 1ml/m
3
)
VOLUMES DE 10 A 250
m
3
Volume to be treated (en m
3
)
Duration of diffusion in mn
Consumption
10
0mn 36sec
10 ml
15
0mn 54sec
15 ml
20
1mn 12sec
20 ml
25
1mn 30sec
25 ml
30
1mn 48sec
30 ml
40
2mn 24sec
40 ml
50 3mn
50
ml
100 6mn
100
ml
150 9mn
150
ml
200 12mn
200
ml
250 15mn
250
ml