7
5.
TECHNICAL DATA
5.1.
Product information sheet. Delegated Regulation (EU) 1254/2014
a)
Supplier's name or trade mark
OXYGEN
b) Model identifier
X-Air C200
c)
Specific energy consumption (SEC), SEC class
A
Cold climate
kWh/m
2
.a -83.8
Average climate
kWh/m
2
.a -40.7
Warm climate
kWh/m
2
.a -16.0
d) Declared typology
Bi-directional,
residential ventilation
e)
Type of drive installed or intended to be
Variable speed drive
f)
Type of heat recovery system
Recuperative
g) Thermal efficiency of heat recovery
%
81
h) Maximum flow rate
m
3
/h
191
i)
Electric power input of the fan drive, including W
106
j)
Sound power level (L
WA
)
49
k)
Reference flow rate
m
3
/s
0.039
l)
Reference pressure difference
Pa
50
m) Specific power input (SPI)
W/(m3/h) 0.33
n) Control factor
0.65
Control typology
Local demand control
o) Declared maximum leakage rate:
internal
%
2.2
external
%
1.2
q) Position and description of visual filter warning
Refer to installation
and operation manual
s)
Internet
address
for
pre-/dis-assembly
www.oxygenvent.com
v)
The annual electricity consumption (AEC)
kWh/m
2
.a 1.7
w) The annual heating saved (AHS)
Cold climate
kWh/a
88.2
Average climate
kWh/a
45.1
Warm climate
kWh/a
20.4