Connect the Fiber OWL 4 BOLT to your fiber link as shown in Figure 3.
Review the end-to-end fiber length, then press
to continue. In the example screenshot
at right, the end-to-end fiber length could be within the range of 1000 to 1006 meters.
The length shown here is what will be entered into the Link Wizard configuration. Press
to
continue.
OPTIONAL:
you may also enter the fiber length manually from this screen.
Enter the number of connections (i.e. patch panels) in the link under test, then press
to
continue.
Enter the number of splices in the link under test, then press
to continue. Splices can be
either fusion or mechanical. Typical multimode networks will have zero splices.
Review your Link Wizard setup.
If correct, press
to continue on to the next step.
If changes need to be made, press
and go back to
.
Press
until the asterisk (*) is in front of 1310nm (as shown at right), then press
to begin
the SET REFERENCE procedure for 1310nm.
Length testing is complete. You may now remove all of the patch cables from the link under test.
Typical fiber networks will have 2 connections – one for a patch panel located at each
end of the link.
some connectors use mechanical splice technology for termination. If the link under
test is terminated with these “no-polish, no-epoxy” type connectors, they should be considered as mechanical splices.
F2
DONE
DONE
DONE
F1
F3
F1
F2
QUICK REFERENCE GUIDES
PAGE 3 OF 5
FIBER A
FIBER B
PATCH FIBER A TO
DONE
END OF THE LINK
^
CONNECT
^
_____________________
FIBER B AT THE FAR
(FIBER PAIR REQUIRED)
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
FIGURE 3
Fiber OWL 4 BOLT
Length Test Connection
LIGHT SOURCE CONNECTOR
PORT NOTES:
– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED
PHYSICAL CONTACT (APC)
CONNECTOR
FIBER LENGTH
01000 -0/+6 meters
TEST
DONE
INDEX
1310nm Index(n)=1 490
_____________________
01000 Meters
02 Connections
00 Splices
YES
NO
INDOOR SINGLEMODE
IS THIS CORRECT?
TIA-568B 3/CAN-T529
_____________________
Standard
»
Length
»
Connections
»
Splices
»
Fiber Type
»
WAVELEN REF dBm
TYP
---------------------
*1310nm NOT SET (-10)
WAVE
SET
DONE
1550nm NOT SET (-10)
SET SOURCE REFERENCES
_____________________
(A CONNECTION IS WHEN
TWO FIBER CONNECTORS
MATE
USUALLY A PATCH
<---
FEET
--->
PANEL)
[2 ]
INLINE CONNECTIONS?
_____________________
SPLICES IN THE FIBER
BEING TESTED:
<---
FEET
--->
[0 ]
ENTER THE NUMBER OF
_____________________
Optical Power Meter:
Fiber OWL 4
Fiber Optic Light Source:
WAVESOURCE Series Singlemode Sources
[1 TO 65535]
<---
UNITS
--->
[01000] METERS
ENTER FIBER LENGTH:
_____________________