Press
to power on the light source.
Press
to power on the Fiber OWL 4.
From the OPERATING MODE menu, press
to highlight SIMPLE METER if necessary, then press
to SELECT.
Compare the reading on the Fiber OWL 4 display to Table 1 for acceptable power levels.
Once proper operation has been verified, remove the straight patch cable from both units and set it aside.
Connect the mandrel-wrapped patch cable between the Fiber OWL 4 and the WaveSource as shown in Figure 4.
Compare the reading on the Fiber OWL 4 display to Table 1 for acceptable power levels.
Press
to return to the OPERATING MODE menu.
RUN LINK WIZARD
From the OPERATING MODE menu, press
to highlight CERTIFICATION METER, then press
to SELECT.
From the START MENU, press
. to start the LINK WIZARD.
F1
F2
DONE
F1
F2
1
ABC
QUICK REFERENCE GUIDES
PAGE 2 OF 5
<1>LINK WIZARD
<2>MAIN MENU
START MENU
Core Size
62.5/125 µM
50/125 µM
Replace at
-22.00 dBm
-25.00 dBm
Acceptable Power Level
-19.0 to -22.0 dBm
-22.0 to -25.0 dBm
TABLE 1
FIGURE 4
Connection for
Mandrel-Wrapped
Patch Cables
LIGHT SOURCE CONNECTOR
PORT NOTES:
– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED
PHYSICAL CONTACT (APC)
CONNECTOR
Optical Power Meter:
Fiber OWL 4
Fiber Optic Light Source:
WAVESOURCE Series Multimode Sources