Press
on the Fiber OWL 4 until the wavelength reads 1310nm.
The Fiber OWL 4 should read approximately -10.00 dBm. If the reading is below -11.00 dBm, the patch cable should be
replaced.
Once proper operation has been verified, remove the first patch cable from both units and set it aside.
Connect the second singlemode patch cable between the Fiber OWL 4 and the Laser OWL as shown in Figure 2.
The Fiber OWL 4 should read approximately -10.00 dBm. If the reading is below -11.00 dBm, the patch cable should be
replaced.
Once proper operation has been verified, remove the second patch cable from both units and set it aside.
Connect the third singlemode patch cable between the Fiber OWL 4 and the Laser OWL as shown in Figure 2.
The Fiber OWL 4 should read approximately -10.00 dBm. If the reading is below -11.00 dBm, the patch cable should be
replaced.
Disconnect the third cable from both units, and set it aside. Press
to return to the OPERATING MODE menu.
RUN LINK WIZARD
From the OPERATING MODE menu, press
to highlight CERTIFICATION METER, then press
to SELECT.
From the START MENU, press
. to start the LINK WIZARD.
From the STORED LINKS menu, press
to highlight the stored link name you wish to use and
press
to SELECT.
OPTIONAL:
you may change the link name to something that better describes the group of fibers
you are testing. Enter the new name for the link, then press
to continue.
Change the LINK DATE to the date of test using the format
MM-DD-YY
, then press
.
Press
to highlight the fiber optic cabling standard, then press
to SELECT.
The date of test must be set so that the correct date appears on certification reports.
If unsure about which cabling standard to use, select TIA-568-B.3.
F3
DONE
F1
F2
1
ABC
F1
F2
DONE
DONE
F1
F2
QUICK REFERENCE GUIDES
PAGE 2 OF 5
<1>LINK WIZARD
<2>MAIN MENU
START MENU
Fiber Link 2
NEXT
SELECT
Fiber Link 3
Fiber Link 4
STORED LINKS
_____________________
Fiber Link 1
<---
SHIFT
--->
[Fiber Link 1
]
LINK NAME:
_____________________
USER DEFINED #1
USER DEFINED #2
NEXT
SELECT
ISO/IEC 11801
FIBER STANDARDS
_____________________
TIA-568B 3/CAN-T529
Optical Power Meter:
Fiber OWL 4
Fiber Optic Light Source:
LASER OWL Series Singlemode Sources
<---
SHIFT
--->
[03-20-08]
DATE: [MM/DD/YY]
_____________________