48 GB/IE
Note:
- Repeat the step 1 to 4 if needed to measure another distance.
- Distance Measurement mode icon
26
will stay on (not flashing)
under single measurement mode.
- Maximum up to 4 measured values can be shown on the
display at a same time.
- If no button is pressed for 30 seconds, the laser and display
back-light will turn off. If no button is pressed for 3 minutes,
the product will power off itself.
Continuous Measurement mode
Continuous measurement involves taking series of measurements
from which the maximum (MAX) and minimum (MIN) values are
displayed. To do this, move the product along a base surface or an
edge from which you wish to the measure a distances. You can, for
example, measure how parallel two opposite walls are or measure
the maximum values while using a function.
1. Start the continuous measurement by briefly pressing the con-
tinuous measurement button
14
. A very short delay could
be observed to get first measured value on the display. This is
common. Now, each measured value will be shown on the
display.
2. Stop the measurement by pressing the continuous measurement
button
14
or MEAS button
16
or return / Clear button
8
. The display now shows the maximum (MAX) and minimum
(MIN) values
21
of that particular measurement series and the
last measured value.