background image

Send SMS 

“INTERVAL*12345678*xxx” to tracker, “INTERVAL” is a command, 

12345678

 is 

password, 

“xxx” is the interval time, which can be set from 30 to 999 seconds. The tracker will send 

back information 

“Set Interval xxx OK”, if the password is not right, the operation is fault, the tracker will 

send back information 

“Wrong Password”. 30 seconds is the default interval time. Longer upload 

interval time can save battery and GPRS data cost, but this will make the total mileage to more error. 

 

9. Set Server IP 

 

Send SMS 

“IP*12345678*58.64.155.133,8011” to the tracker, in which, “IP” is the fixed command, 

12345678

 is the password and 

“58.64.155.133,8011” is the IP address of the server computer of our 

website. Having successfully been set, there will be a SMS 

“IP: 58.64.155.133,8011”. However, the IP 

address may be changed with the upgrade of our server, so please see to the notices on our website. 

 

Notice: The tracker IP address has been set to default : 58.64.155.133,8011 in factory, it is not 

necessary to set again, unless our IP address has been changed or user need upload the location 

to other server, If our server IP is changed, we will notice on the website. 

10. Check tracker setting 

 

Send SMS 

“CHECK*12345678” to tracker, “CHECK” is the fixed command, 

12345678

 is 

password. The tracker will send back information including software version, ID S/N number, IP 

address, authorized phone number, GPS and GSM signal etc. if the password is not right, the operation 

is fault, the tracker will send back information 

“Wrong Password”. The following is an example : 

 

V Mar 18 2019,CC830,000830019820800,58.64.155.133,8011,30,A:13987654321, 

B:13876543210, GPS OK,+00,-95dBm,ShockControl,CMNET,User,Password,46000,e1d/24a0,93% 

V Mar 18 2019,

 

;Software version date 

 

CC830,

 

;TCP/IP Protocol name 

 

000830019820800,

 

;ID S/N number 

 

58.64.155.133,8011,

 

;Server IP and Port 

 

13987654321,

 

;Authorized number (A/B/C) 

 

GPS OK ,

 

;GPS status 

 

+00,

 

;Time Zone (00 means GMT time) 

 

-95dBm,

 

;GSM signal strength 

 

ShockControl,

 

;GPRS is controlled by shock sensor 

 

CMNET,

 

;APN name 

 

User,

 

;GPRS user name 

 

Password,

 

;GPRS password 

 

46000,

 

;Sim Card MCC+MNC 

 

-

11

Summary of Contents for PL641

Page 1: ...4G GPS Portable Tracker User Manual PL641 1...

Page 2: ...in shock sensor for shock alarm User change work report mode by sms Auto configure APN Use external power box connect to car battery can be used as car gps tracker Suit for personal or vehicle tracki...

Page 3: ...ation to server this kind of M2M SIM card can not use SMS locate alarm 2 This tracker use standard SIM card please see the following diagram to select the SIM card 3 Some SIM card need to send SMS or...

Page 4: ...nd send battery low alarm information to authorized number and later if the battery power is too low it will power off automatically 6 Back to Factory Setting Default Setting Sending SMS FACTORY 12345...

Page 5: ...ation can not update on the app website and the red LED will flash twice then you need send SMS to tracker to change the APN GPRS manually send SMS CHECK 12345678 to tracker to check the APN configura...

Page 6: ...ssword the tracker will send back the information Set Shock Alarm ON to indicate the operation is success and go to arm state if the password is not right the operation is fault the tracker will send...

Page 7: ...114 15188E Battery 91 If no authorized number is added the SOS information can not be sent If the SOS information is received please confirm the user is safety Settings Commands 1 Set Tracker Working...

Page 8: ...ce sms standby the tracker will not cost any data charge only SMS charge is needed This mode is suit for outdoor personal using the working time can be very long the standby time can be reach over 1 m...

Page 9: ...mobile phone to locate the tracker without platform if the authorized phone number is not set then the alarm information can not send to user by SMS alarm information SOS etc 4 1 Add authorized phone...

Page 10: ...can check or change the password 6 Set Alarm by Calling ON OFF Send SMS CALLON 12345678 Call to authorized number or CALLOFF 12345678 No calling to the tracker CALLON or CALLOFF is a command 12345678...

Page 11: ...58 64 155 133 8011 in factory it is not necessary to set again unless our IP address has been changed or user need upload the location to other server If our server IP is changed we will notice on the...

Page 12: ...ter 12 Restore to factory setting Back to Default Send SMS FACTORY 12345678 to tracker can make the tracker power off and power on again FACTORY is the fixed command 12345678 is password The tracker w...

Page 13: ...installed properly the SIM card PIN code is disable and the SIM card has enough charge and the mobile phone can work well in that place If the tracker work well the Green LED will flash once every 4...

Page 14: ...and B1 B3 B38 B39 B40 B41 GPS BeiDou Dual module N303 2 3 4G GPS Antenna Internal Internal Locate precision 5 10 Meters GPS Hot Start Time 1 second average GPS Cold Start Time 36 seconds average Track...

Reviews: