Required items needed to complete this installation and special installation notes:
Opener will require an Auxiliary Output Module (AOM). P/N OPABIOX.S
Opener will require a monitored safety device such as ODC/STB photocells or T3 Monitored
edge system.
Opener will require a 24vac Transformer Kit:
•
111087.0004.S 1phase kit
•
111087.0005.S 3ph kit
•
111087.0006.S 575V 3ph kit.
Opener will require an external receiver if using remote controls for countdown operation.
DO NOT use internal receiver with this Countdown Timer Kit.
If a monitored edge is used in conjunction with a monitored photocell, a Timer Close Module
(TCM) part number OPABTCX.S or Edge Sensing Module (ESM) part number OPABESX.S is
required. Move the YELLOW wire from the NO REVERSE terminal on the main board to the
MON EDGE terminal on the TCM/ESM. See Note 1 Page 12 & 13.