background image

I

nstallation instructions

Thermostat “Uni XH”
M 30 x 1.5

1.  Turn thermostat to position “5”.
2.  Adjust the thermostat in such a way that the mark (below

    the Oventrop name) is well visible.

3.  Hold the thermostat in this position and tighten the collar

    nut (do not use excessive force).

4.  The capillary must not be kinked or flattened! The remote

    sensor is mounted onto the wall next to the radiator (about
    1 m above the floor) in horizontal position.

Thermostat “Uni XD”
with squeeze connection

Valves, co systems

Thermostat “Uni XH” and “Uni XD” with remote sensor

Operating instructions

1.  Set thermostat to position “5” (f) and screw back collar nut

    (e) completely as illustrated.

2.  Slip  thermostat  onto  valve  body  until  stop  (a).  Turn 

    thermostat  slightly  to  the  left  or  right  until  the  inner  cams 
    (c) and grooves (b) click into position.

3.  Firmly  push  thermostat  towards  the  valve  body  (g)  and 

    firmly tighten the collar nut (e) towards the collar (d).
    Do not damage collar nut!

4.  The capillary must not be kinked or flattened! The remote

    sensor is mounted onto the wall next to the radiator (about
    1 m above the floor) in horizontal position.

Description

Collar nut
”Lower limiting clip”
”Upper limiting clip”
Indicator mark (with tactile set-

ting device in form of a ridge)
Minor graduation
Graduation number
Direction “warmer”
Basic setting “3”, about 20 °C 

(with tactile setting device in 

form of a point)
Direction “colder”
Handgrip

Memory disc

Remote sensor

Temperature setting

Setting of desired temperature

The  desired  temperature  is  set  by  rotating  the  thermostat  to
the desired number until it is opposite the indicator mark.
The minor graduations between the figures “2” and “4” repre-
sent a change of the room temperature of about 1°C.

                     

Examples:

about 28 °C

 Swimming  pool  (in  order  to  save 

                     heating  costs,  the  control  range  bet-
                     ween “4” and “5” should be avoided)

about 24 °C  Bathroom

                     Living room, dining room
about 20 °C  Basic setting “3”
                     Children’s room

about 16 °C  Hall, corridor
                     Workshop, sleeping room

about 12 °C  Cellar

about 

1

7 °C  Frost protection

                     Isolation of the radiator (only for
                     model with ”0” setting)

The indicated temperatures are only achieved if the complete
heating installation was designed accordingly!

Temperature setback

To  save  heating  costs,  the  room  temperature  should  be  set
back  at  night  or  during  longer  absence.  To  do  so,  the  ther-
mostat  is  to  be  set  to  a  lower  value,  e.  g.  from  figure  “3”  to
“2”.
Temperature  should  also  be  set  back  if  rooms  are  not  used
for several hours.

Cleaning

The  thermostat  may  only  be  cleaned  with 

mild

detergent

which is added to warm water.
Scouring  agents,  solvents  and  aggressive  detergents  cause
damage  to  the  surface  of  the  thermostat.  It  may  not  be 
cleaned in a dish washer.

Disposal

To  protect  the  sensor  liquid  from  escaping,  the  thermostat
must  not  be  destroyed  when  disposed  of.  The  thermostat
contains  hazardous  waste!  Dismounted/defective  thermos-
tats can be returned to the manufacturer Oventrop. They will
be disposed of professionally.

Marking of a set temperature

The  Oventrop  thermostat  is
equipped  with  a  memory  disc
which  facilitates  the 

reproduc-

tion

of your desired temperature

after  having 

turned

the  ther-

mostat 

to a different position.

This  is  done  by  means  of  the
memory disc which can be rota-
ted  with  the  aid  of  a  small  coin
so that the 

notch

, the setting of

your 

desired  temperature

and

the 

indicator mark

are in line.

After  having  turned  the  ther-
mostat  to  a  different  position,
your desired temperature can be
restored as follows:

Turn  the  handgrip  so  that  the
notch  on  the 

memory  disc

and

the  indicator  mark  are  in  line
again.

Limiting the control range

The  temperature  range  may  be  limited  if  required,  with  the
two limiting clips.
The  thermostat  may  be  limited  to  each  minor  graduation,
figure and the frost protection symbol.

Example: 

Your  desired  room  temperature  is  between  about 

16 °C (figure “2”) and about 22 °C (figure “3” plus two minor
graduations).

For limiting the 

maximum

temperature

range, turn the thermostat so the desi-
red max. room temperature, e.g. figure
“3”  plus  2  minor  graduations  (about 
22 °C), is in front of the indicator mark -
illustration  1.  Now,  slide  the  right 
limiting  element  out  of  the  parking
position  into  the  limiting  position  -
illustration 2 (if required, the thermostat
has to be moved a little bit).

For  limiting  the 

minimum 

temperature

range,  turn  the  thermostat  so  the 
desired  min.  room  temperature,  e.g.
figure  “2”  (about  16  °C),  is  in  front  of
the  indicator  mark.  Now,  slide  the  left
limiting  clip  out  of  the  parking  position
into the limiting position - illustration 3.
Now  only  the  chosen  temperature
range can be used.
To cancel the limitation, the thermostat
is turned so the chosen min. and max.
temperature is in line with the indicator
mark.  Then  the  limiting  elements  are
put back in the parking position.

Locking a set value

If a set temperature is to be locked, e.g.
position “3” (about 20 °C), i. e. an acci-
dental  change  of  temperature  shall  be
avoided,  a  set  value  can  be  locked  by
sliding 

both 

(left and right) limiting clips

out  of  the  parking  position  into  the
limiting  position  at  the  same  time  - 
illustration 4.

This  lock  can  be  cancelled  by  simply  sliding  both  limiting
clips back into the parking position.

The  thermostat  may  be  locked  at  any  minor  graduation,
graduation number and the frost protection symbol.

Airing of rooms

As the air is used up very fast during the heating period, the
rooms  should  be  aired  by  opening  the  windows 

wide  for  a

short period

.

Before  airing  the  room,  the  thermostat  should  be  turned  to
the frost protection symbol. The airing being completed, the
thermostat  is  turned  back  to  its  initial  position.  Should  the
temperature  range  have  been  limited,  set  the  thermostat  to
the minimum temperature.

Illustration 1

Illustration 2

Illustration 3

Illustration 4

GB

Subject to technical modification without notice.

101156580  11/2010

For an overview of our global presence visit
www.oventrop.com.