en
15
Installation
Commissioning
Adjustments
Tr
oubleshooting
Data comm
unication
3.2
Status menu
In the
Status
menu of the controller, the status mes-
sages for every menu area can be found.
3.2.1 Meas. / Balance values
In the
Status / Meas. / Balance values
menu, all
current measurement values as well as a range of
balance values are displayed. Some of the menu items
can be selected in order to enter a sub-menu.
All measured values for the main and additional func-
tions, the allocation of sensors and relays as well as
the operating hours counter are displayed.
If, for example,
Hot water
is selected, a sub-menu
with the sensors and relays allocated to the system
will open. In the sub-menu, the current temperatures
and the current pump speed are indicated.
When a line with a measurement value is selected,
another sub-menu will open.
If, for example,
VFD
is selected, a sub-menu indicat-
ing the minimum and maximum values will open.
When the item
Chart
is selected, a progression
chart appears.
The progression chart shows the development at the
corresponding sensor over the last 24 hours. Press
buttons
❷
and
❹
to switch back and forth between
a chart of the current day and one of the day before.
3
Adjustments
3.1
Main menu
In this menu, the different menu areas can be se-
lected.
The following menus are available:
Status
Hot water
Circulation
Afterheating
Disinfection
Additional functions
Basic setting
SD card
Manual mode
User code
Inputs
Note:
If no button is pressed for the adjustable
time
T-display standby
(see page 32),
the display illumination goes out. After 3
more minutes, the controller switches to
the Status menu.
Î
In order to get from the Status / Hot
water menu into the Main menu, press
button
➆
.