34
Rail installation
B
C
A
2
30 Nm
1
Illustr. 13: Rail installation with specification of the distance between the roof anchors with 4 roof hooks per collector (application limits see
table)
Design examples for snow and wind load zone 1-2*
Height of
building[m]
Height above
sea level [m]
Rooftop installation (number of
roof anchors per collector)²
10
400
4
10
800
6
10-20
400
4
10-20
800
6
* 45° inclination without taking the installation in the edge and
corner regions of the roof into account
Section
Distance [mm]
A
approx. 1.000
B
1.815-2.175
C
20-200