• Connecting LP Gas Tank
• Disconnecting LP Gas Tank
• Connecting NG
• Disconnecting NG
This appliance can use two types of fuel/gas: LPG-Propane OR Natural Gas
Suitable LP gas tank size for this appliance is 20 lb (9.1 kg)
The inlet gas supply pressure for the purpose of input adjustment pressure:
LPG-Propane 28 cm (11 in) w.c. (2.74kPa)
Natural Gas 18 cm (7 in) w.c. (1.74kPa)
The appliance must be isolated from the gas supply piping system by closing its individual
pressures equal to or less than 1/2 psi (3.5kPa).
The LP-gas supply cylinder to be used must be:
• Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)
•
device compatible with the connection for the appliance.
WARNING: Make sure LP gas tank valve is closed. Close by turning valve clockwise.
Place the LP gas tank upright into the tank tray and secure the tank by screw.
CONNECTING AND DISCONNECTING LP & NG
Before connecting, be sure that there is no debris
caught in the head of the LP gas tank, head of
the regulator valve or in the head of the burner
and burner ports.
Connect regulator/hose assembly to tank by
turning knob clockwise.
Before disconnecting make sure the LP gas tank valve
is "CLOSED."
Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
Caution: LP gas tank must be properly disconnected
and removed prior to moving this pit.
1.
recommended, but not required, by the National Fuel Gas Code. Socket connection
must be made outdoors.
2.
supply pipe (house gas source), and wrench-tighten.
3. Pull back the sleeve on the quick disconnect socket and insert the unattached end of the gas hose into the
socket. Release the sleeve and continue pushing the hose into the socket until the sleeve snaps into the
locked positon.
4. When the quick disconnect socket and the gas hose are connected, a valve in the socket opens automatically
from the quick disconnect socket. The socket should be left attached to the gas source (hose piping).
With proper assembly, the gas hose cannot be removed without pushing the quick disconnect sleeve back. To
that system at test pressures in excess of 1/2 psi (3.5kPa).
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
LP GAS
NG
Figure 236, Page 10
Summary of Contents for 1902301
Page 1: ...11 236 1 1902301 OVE r 1 866 839 2888 2800 rue tienne Lenoir Laval Qu bec H7R 0A3 Canada...
Page 2: ...ANSI Z21 97 2014 ANSI Z233 1 NFPA 54 CSAB149 1 B149 2 236 2...
Page 3: ...236 3 ANSI NFPA 58 DANGER 90 3 90 3 1 8 6...
Page 4: ...236 4 ANSI Z233 1 CANADA CAN CGA B 149 2 CO CO...
Page 6: ...236 6 4 x 2...
Page 7: ...1 2 236 7...
Page 8: ...3 4 236 8 20 LBS...
Page 9: ...5 236 9 6...
Page 11: ...1 50 50 2 OFF 3 4 A B C D E F G H 5 A H 6 7 8 OFF 9 10 11 12 236 11 60...
Page 12: ...1 x 7 AAA 236 12...
Page 13: ...1 2 3 236 13...
Page 15: ...ON OFF ON ON 4 4 40 1 4 236 15...
Page 16: ...1 2 1 2 3 1 2 3 4 5 6 7 8 9 1 2 3 4 OFF OFF 236 16...
Page 26: ...ASSEMBLY INSTRUCTIONS FOR LP Figure 236 Page 9 Step 5 Step 6...
Page 29: ...BATTERY INSTALLATION 1x AAA Battery included Figure 236 Page 12...