FUNCTION

Select Switch

 

Selects

INPUT COUNTER

functions.

 “

COUNT

” …… 

Accumulated total counter

         

  Counts the number of incoming pulses at

SIG

terminals.

 “

FREQ 1S

”…… 

Frequency counter with one second gate

         

  Counts the number of incoming pulses at

SIG

terminals for a period of one 

                                   second 

 Displays it for one second 

 Reset to

0

. The cycle above is

                                   repeated.

         

   Unit of measure displayed on the counter

 …… “

Hz

” 

 “

FREQ 10S

” …

   Frequency counter with 10-second gate

         

  Counts the number of incoming pulses at

SIG

terminals for 10 seconds 

 2 

                                   sec. hold displayed 

→“

0

reset.

         

  This cycle is repeated.

         

  Unit of measure displayed on the counter

 …… “

Hz

 “

PERIOD

  

…… 

Period counter with 1MHz pulses

         

  Counts the period of incoming pulses at

SIG

terminals against the 1MHz 

                                  internal pulses and displays it, latched.

         

 Unit of measure displayed on the counter

 …… μ

s

 “

RATIO

” 

 

…… 

Gated accumulated total counter

         

 Counts the number of incoming pulses at

SIG

terminals at the intervals of 

                                  pulses incoming through

GATE

terminals and displays it, latched.

  (4)

RESET

Pushbutton Switch

   

  

Upon depression, the

INPUT COUNTER

is reset to

0

.

  (5)

INPUT COUNTER

  

  

An 8-digit LCD accumulated total counter. Its functions are selectable with

FUNCTION

select switch.

3. Output Functions

  (1)

FREQUENCY

Preset Switch

  

Establishes the reference frequency of output pulses with 4-digit decade switch.

  

Preset coverage: 1 to 9999Hz (in 1Hz steps)

  (2)

RATING

Select Switch

  

Selects the decimal point of the

FREQUENCY

reference frequency.

  “

1

” 

  

…… 

The decimal point of 4-digit decade switch is 

□□□□

. Hz

  “

10

” …… 

The decimal point of 4-digit decade switch is 

□□□

.

 Hz

  “

100

”…… 

The decimal point of 4-digit decade switch is 

□□

.

□□

 Hz

  “

1K

” …… 

The decimal point of 4-digit decade switch is 

.

□□□

 Hz

  “

10K

”…… 

The decimal point of 4-digit decade switch is 0.

□□□□

 Hz

  (3)

% SETTER

Select Switch

  

Selects % frequency reduction of the reference frequency.

  “

100

”…… 

Provides the reference frequency output with the decimal point chosen as above.

  “

75

” …… 

Provides the reference frequency output 

×

0.75 with the decimal point chosen as above.

  “

50

” …… 

Provides the reference frequency output 

×

0.5 with the decimal point chosen as above.

  “

25

” …… 

Provides the reference frequency output 

×

0.25 with the decimal point chosen as above.

  “

0

  

 …… 

No output is provided.

  (4)

PRESET

Switch

  

Presets the number of output pulses with 8-digit decade switch.

  

Upon

START

button depression, the checker produces the number of pulses preset before it

       comes to stop pulse generation automatically.

  

Preset coverage: 1 to 99999999 P (in 1P steps)

Summary of Contents for PC2201

Page 1: ...SE CHECKER This product is fabricated and shipped from our factory under stringent quality control With the proper application of the information and knowledge contained in this manual you will be abl...

Page 2: ...OTE CAUTION and WARNING as explained below NOTE Notes are separated from the general text to bring the user s attention to important information CAUTION Caution statements inform the user of hazards o...

Page 3: ...t LCD Input counter 6 RESET Input counter reset pushbutton switch 7 INPUT Input terminals to banana plugs of the furnished cords 8 FREQUENCY 4 digit decade switch for establishing the reference freque...

Page 4: ...TION 1 6 SCALER 1 100 END BUZZER BATCH CONTROL CIRCUIT FREQ REDUCTION 8 DIGIT DECADE SWITCH 8 DIGIT LCD DISPLAY COUNT COLLATE OUTPUT COUNTER OUTPUT SIGNAL SELECT CKT PULSE WIDTH SHAPING STABILIZED VOL...

Page 5: ...batteries should be replaced every year although their life may vary depending on the given operating conditions 2 Input Functions 1 INPUT terminals SIG Input terminals to accept pulse signals with se...

Page 6: ...total counter Its functions are selectable with FUNCTION select switch 3 Output Functions 1 FREQUENCY Preset Switch Establishes the reference frequency of output pulses with 4 digit decade switch Pre...

Page 7: ...nhibited while the green COUNTING LED is illuminated however When the accumulated total count on the OUTPUT COUNTER has reached the PRESET count the checker shuts off pulse output generation automatic...

Page 8: ...t of PG30S generator circuit O C A simulated output of FLOWPET NX or PG60A E generator circuit VOLT A voltage pulse output from 8V internal power source PA11 A simulated output of PA11 generator circu...

Page 9: ...0V Vcc 8 5V GND 0V 1k 7 4V 5 6V PC2201 OUTPUT OPTO Vcc 13 5V GND 0V 10k RECOMMENDATION R 10k R 10k 13 4V 0 1V PG20 PG30 Vcc 24V GND 0V 510 22 0V 14 3V P A Vcc 13 5V 30mA GND 0V 10k 6 5V 0 1V Vcc 13 5V...

Page 10: ...GND 0V 10k min 31 9V 1 0V 30mA 0 25 or 1 or 50ms 0 25 or 1 or 50ms PC2201 RECEIVING INSTRUMENT SIG WAVEFORM Voltage levels of signal waveform include an error of 0 5V Signal waveforms shown here indic...

Page 11: ...1 External connection cords terminated with alligator clip and banana plug Red 4 black 2 6 OUTLINE DIMENSIONS 7 STANDARD ACCESSORIES HANDLE SLOT AC ADAPTOR SLOT POWER SWITCH SLOT SOFT CASE 1 EA ACCESS...

Page 12: ...E 935 1 E 2 All specifications are subject to change without notice for improvement 2019 02 Revised E 935 1 E 1...