background image

E-935-1-E

5

4.  DESCRIPTION OF FUNCTIONS

. Power Functions

   (1)

DC IN

connector

…… 

Connects to the furnished AC adaptor.

   (2)

POWER

switch  

…… 

Furnishes power to the circuitry when turned on. The Input and output counter 

                                                LEDs light up at the same time.

This checker operates on a two-way power supply system. When this switch is turned on with no 
external  power  furnished  through  the  ac  adaptor,  the  instrument  operates  on  internal  batteries. 
The  batteries  are  of  rechargeable  type  and  good  for  about  5  hours  of  operation  if  fully  charged  in 
24 hours. (Connected to an external power source through the ac adaptor, the batteries will be fully 
charged in 24 hours with power switch off.)
When the battery terminal voltage drops below serviceable level, the input and output counter LCDs 
begin to flicker.)
Although the checker is serviceable for 10 to 15 minutes with the LCDs flickering, it is recommended 
that the batteries be recharged immediately or an ac power be furnished through the ac adaptor to 
eliminate possible erratic operation.
The  batteries  should  be  replaced  every  year,  although  their  life  may  vary  depending  on  the  given 
operating conditions.

2. Input Functions

   (1)

INPUT

terminals

 

       

SIG

” 

 

…… 

Input terminals to accept pulse signals with selectable trigger level.

 

       

GATE

”…… 

Input terminals to accept gate pulses.

        

    

 

Trigger level: 2.5V

  

Hysteresis: 0.1V

         

    Pulse width response: 1

μ

s min.

         

    Frequency response: 5Hz max.

 

       

0V

:

 

  

…… 

Common 0V line

   (2)

INPUT LEVEL

Select Switch

 

This checker has no internal power supply for pulse generators. It therefore cannot drive directly the 
pulse generators described in the“Receive Signal”columns above.
So, couple with other receiving instrument which has an internal power supply and pick up its signal only. 
In case of PA04, 05, 45 or PG60A (E), it may be“6”depending on the position of picking up the signal.

Select

Trigger Level

Hysteresis

Response Freq.

Receive Signal

15

1.5V

0.1V

300kHz

Voltage pulse signal at IC level

OC

11.3k

Ω

20k

Ω

10kHz

Pulse signal of no voltage (W/pull up resistor)

3

3.0V

0.1V

10kHz

PG30

6

6.0V

0.2V

10kHz

PG30S

18

18.0V

0.6V

10kHz

PA04, 05, 45 and PG60A (E)

[18]IS CHOSEN

[6]IS CHOSEN

P C 2 2 0 1

P C 2 2 0 1

SIG

SIG

INPUT

INPUT

0V

0V

PULSE

GENERATOR

PULSE

GENERATOR

510Ω

510Ω

24V

24V

SIG

SIG

0V

0V

RECEIVING INSTRUMENT

CAUTION:

CAUTION:

Summary of Contents for PC2201

Page 1: ...SE CHECKER This product is fabricated and shipped from our factory under stringent quality control With the proper application of the information and knowledge contained in this manual you will be abl...

Page 2: ...OTE CAUTION and WARNING as explained below NOTE Notes are separated from the general text to bring the user s attention to important information CAUTION Caution statements inform the user of hazards o...

Page 3: ...t LCD Input counter 6 RESET Input counter reset pushbutton switch 7 INPUT Input terminals to banana plugs of the furnished cords 8 FREQUENCY 4 digit decade switch for establishing the reference freque...

Page 4: ...TION 1 6 SCALER 1 100 END BUZZER BATCH CONTROL CIRCUIT FREQ REDUCTION 8 DIGIT DECADE SWITCH 8 DIGIT LCD DISPLAY COUNT COLLATE OUTPUT COUNTER OUTPUT SIGNAL SELECT CKT PULSE WIDTH SHAPING STABILIZED VOL...

Page 5: ...batteries should be replaced every year although their life may vary depending on the given operating conditions 2 Input Functions 1 INPUT terminals SIG Input terminals to accept pulse signals with se...

Page 6: ...total counter Its functions are selectable with FUNCTION select switch 3 Output Functions 1 FREQUENCY Preset Switch Establishes the reference frequency of output pulses with 4 digit decade switch Pre...

Page 7: ...nhibited while the green COUNTING LED is illuminated however When the accumulated total count on the OUTPUT COUNTER has reached the PRESET count the checker shuts off pulse output generation automatic...

Page 8: ...t of PG30S generator circuit O C A simulated output of FLOWPET NX or PG60A E generator circuit VOLT A voltage pulse output from 8V internal power source PA11 A simulated output of PA11 generator circu...

Page 9: ...0V Vcc 8 5V GND 0V 1k 7 4V 5 6V PC2201 OUTPUT OPTO Vcc 13 5V GND 0V 10k RECOMMENDATION R 10k R 10k 13 4V 0 1V PG20 PG30 Vcc 24V GND 0V 510 22 0V 14 3V P A Vcc 13 5V 30mA GND 0V 10k 6 5V 0 1V Vcc 13 5V...

Page 10: ...GND 0V 10k min 31 9V 1 0V 30mA 0 25 or 1 or 50ms 0 25 or 1 or 50ms PC2201 RECEIVING INSTRUMENT SIG WAVEFORM Voltage levels of signal waveform include an error of 0 5V Signal waveforms shown here indic...

Page 11: ...1 External connection cords terminated with alligator clip and banana plug Red 4 black 2 6 OUTLINE DIMENSIONS 7 STANDARD ACCESSORIES HANDLE SLOT AC ADAPTOR SLOT POWER SWITCH SLOT SOFT CASE 1 EA ACCESS...

Page 12: ...E 935 1 E 2 All specifications are subject to change without notice for improvement 2019 02 Revised E 935 1 E 1...

Reviews: