background image

MODEL

EL4001

TB

1

TB

2

TB

1

TB

2

TB

3

PLS  OUT3

TEMP

  IN

TEMP

  IN

FLOW  IN

0V

B

b

A

SIG

SUP

SUP

ANA

  OUT

GND

POWER

N

H(

PRESS  IN

PLS  OUT1

PLS  OUT2

1/1 OUT

E-886-2-E

2. GENERAL

In  comparison  with  the  previously  offered  instruments  (OVAL  EL4080  series),  substantial  reduction  in 

physical geometry, improved functions and ease of operation have been achieved. Included among the 

improvements in this newly developed instrument are simplified parameter changes and data logging with 

IC cards along with a large, easy-to-read LCD display.

Table 2.1

Model

Description

EL4301

This  instrument  receives  tube  oscillation  signal  and  temperature  signal  from  the  OVAL 

Coriolis flowmeter and, upon calucation, displays the density of process fluid.

It also can display the density corrected for reference temperature and provide an analog 

output.

EL4311

This instrument receives mass flow signal and temperature/density signals from the OVAL 

Coriolis flowmeter and, upon calucation, displays the total flow of solids content of process 

fluid that contains solids.

It also can display the density corrected for reference temperature and provide an analog 

output.

EL4321

EL4331

This  instrument  receives  density  frequency  signal  from  the  density  sensor  and  provides 

an analog output in proportion to the density of metered process fluid. In response to tem-

perature  and  pressure  signals  (EL4321  only),  it  also  can  provide  an  output  corrected  for 

reference conditions.

2.1 Features

(1) Performs calculation of density corrected for temperature.

(2) Changing the ranges of density, temperature, pressure, or other parameters, of the companion densi-

tometer is simple by keystrokes on the front-panel keypad or by inserting an IC card into the slot.

(3) A built-in CPU offers a high degree of performance and accuracy.

(4) Variables such as temperature, pressure, and density can be reviewed on command with the front 

panel keypad, whether or not computation is in progress.

(5) A nonvolatile memory (E

2

PROM) retains all parameters in the event of an AC power failure.

(6) Displays  the  percent  concentration  of  solids  content  in  the  slurries  and  provides  its  analog  output 

(EL4301 only).

(7) Produces high and low density alarm outputs (set to desired limits) (EL4301 only).

(8) If an error occurs, its nature is identified as an error message on the display.

2.2 Part Names and Functions

Fig. 2.1  Part Names

Function Keys

Display

IC Card (option)

Shift Keys

Seal Screw

Terminal Blocks

Summary of Contents for EL4301

Page 1: ...of these instruments Keep this manual for ready reference It is suggested that the instruction manuals for the companion pulse generator flowmeter and receiving instrument be referred to at the same...

Page 2: ...OMPONENTS AND FUNCTIONS 12 6 1 Front Panel 12 6 1 1 Display 12 6 1 2 Front Panel Keypad 12 6 1 3 Error Messages 12 6 1 4 Display Items 13 7 CALCULATION FORMULAS 15 8 PREPARATIONAL CHECKS AND OPERATION...

Page 3: ...170 9 ABOUT EL4501 175 10 DIP SWITCH CONFIGURATION 182 Model with communication capabilities COMMUNICATION MANUAL Ins No E 880CM E CONTENTS 1 COMMUNICATION CAPABILITY OVERVIEW 5 2 NETWORK CONFIGURATI...

Page 4: ...d 11 When you inquire supply complete infor mation as to the product name model number product number ratings and other pertinent information 1 2 Transportation Precautions 1 In order to safeguard aga...

Page 5: ...nd provide an analog output EL4321 EL4331 This instrument receives density frequency signal from the density sensor and provides an analog output in proportion to the density of metered process fluid...

Page 6: ...0 centimeters from the back panel of the instrument to facilitate wiring and servicing 3 2 2 Panel 1 Use a rigid steel sheet with a minimum thickness of 1 6 millimeters 3 2mm thick is recommended 2 If...

Page 7: ...r circuits to minimize the possibility of inductive interference 3 Using crimp type lugs for wiring ensure good electrical coannections Terminals are found on the back of the instrument Fig 4 1 4 3 De...

Page 8: ...3 0V 14 0V 4 OUT 1 1 15 5 b Temp in 16 6 B 17 Temp in 7 A 18 Comm 1 8 19 9 20 Comm 2 10 Alarm out 21 11 NOTE Model provided with communication interface NOTE If transmitter MT9411 temperature termina...

Page 9: ...Pulse out 3 No polarity Alarm out Static relay 11 12 Density in SUP 13 SIG Tube period signal 5V square wave 14 0V TB2 No Label Description 1 2 3 4 Analog out Instant solids content flow 4 to 20mADC...

Page 10: ...Code Description Model E L 4 3 1 1 Density Computer for Mass Flowmeter with solids content calculation feature Power 6 20 to 30VDC Power consumption 20W max 7 85 to 264VAC 50 60Hz Temperature Input 0...

Page 11: ...1 Density corrected for temperature and pressure 9 Other than above special Communication Capability 0 No 1 Yes Finish 1 Munsell N1 5 Table 5 4 EL4331 Product Code Explanation Item Product Code Descr...

Page 12: ...ving between menu items or changing numerical values 6 1 3 Error Messages When an erratic condition arises an error message automatically appears on the display NOTE The information represented by err...

Page 13: ...plays it If it exceeds preset high or low limit its default fallback value is shown Total Mass Flowrate TOTAL COUNT Displays mass flow corrected for meter error Total Mass Flow of Solid Content TOTAL...

Page 14: ...re pressure and density currently coming in and displays it Specific Weight SPECIFIC WEIGHT Calculates specific weight based on the temperature pressure and density currently coming in and displays it...

Page 15: ...Xs Da Db Dx Dc Dx2 Ta Tb tx Tc tx2 100 where Xs Solids proportion Da to Dc Ta to Tc Coefficients to determine Xs Instant flowrate of solids content EL4311 Xs E Qsr Qr kg h Qr a f 1 3600 kg h 100 100 w...

Page 16: ...instrument operates with no fluid flow How to Check 1 Couple sources of simulated temperature and pressure signals 2 Using the shift keys select menu items and verify the information displayed NOTE Se...

Page 17: ...ulty 2 Pressure transmitter is faulty 3 A fault in internal assembly Faulty meter error correction factor and or temperature correction factor 1 Temperature and pressure readings correct 1 A fault in...

Page 18: ...2 OVER Analog pressure input 2 overflow 25 PRESS 2 UNDER Analog pressure input 2 underflow 26 DENSITY OVER Density input overflow 27 DENSITY UNDER Density input underflow 28 4mA SCALER 1 UNDER Analog...

Page 19: ...Std Span 200 C 10mV C Range 50 to 150 C 5 V C Range 100 to 200 C Density 0 0000 to 6 0000g ml Com puting accuracy ULTRA mass MKII CN series Density before correction 0 001g ml Factory calibration acc...

Page 20: ...cimal place Solids content proportion To the 2nd decimal place Error alarm Number of errors error messages Com puting range Temperature Pt 100 at 0 C Range 50 to 200 C Std span 70 C 4 to 20mADC or 1 t...

Page 21: ...ted Pressure To the 4th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error...

Page 22: ...th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error messages Com puting r...

Page 23: ...r Multi plexer Press Input Ckt analog Temp Input Ckt analog Temp Input Ckt Pt Analog Output Circuit Pulse Output Circuit 1 Pulse Output Circuit 2 Pulse Output Circuit 3 I O Board CPU Board Communicati...

Page 24: ...E 886 2 E All specifications are subject to change without notice for improvement 2017 01 Revised 2008 08 Released E 886 2 E 1...