12.2 EL4311 Density Computer for Mass Flowmeter (with solids proportion calculation feature)
Table 12.2
Item
Description
Input
signals
Flow input
2-wire voltage pulse
Speed of response 2kHz
Open collector pulse
Temp. input
Resist. thermo-
meter bulb
Pt 100
Ω
at 0
°
C, 3-wire system Rated current 2mA
Analog
4 to 20mADC or 1 to 5VDC, 10mV/
°
C, 5mV/
°
C
Density input
Tube period signal (from L.H. sensor)
±
5V square wave
Output
signals
Pulse output
Total mass flow
Static relay Capacity: 230AC/340VDC 0.2A
Pulse width: 1ms/50ms
Total solids content
Output sync with flow input
Open collector pulse
Alarm output
Static relay Capacity: 230VAC/340VDC 0.2A
Analog output
Instant mass flow
Instant solids content rate
Solids proportion or
corrected density
4 to 20mADC (Max. load resistance 500
Ω
)
or 1 to 5VDC (Output impedance 250
Ω
)
Conversion accuracy:
±
0.1% of F.S.
Display type
Display: ST display (128
×
128 dots), backlighted (
※
1), (
※
2)
Information displayed: Data, units, error message simultaneously
Menu
Items
Density before correction
To the 4th decimal place (g/ml, etc.)
Corrected density
To the 4th decimal place (g/ml, etc.)
Total mass flow
Same as the output pulse unit (kg, etc.)
Count capacity: 8 digits
Total mass flow of solid content Same as the output pulse unit (kg, etc.)
Instant mass flowrate
kg/h, etc.
Instant mass flowrate of solid content kg/h, etc.
Temperature
To the 2nd decimal place (when
°
C is selected.)
Density period
To the 1st decimal place (when
μ
s is selected.)
Meter error correct. factor
To the 5th decimal place
Solids content proportion
To the 2nd decimal place (%)
Error alarm
Number of errors
+
error messages
Com-
puting
range
Temperature
Pt 100
Ω
at 0
°
C
Range:
-
50 to
+
200
°
C
Std. span: 70
°
C
4 to 20mADC or 1 to 5VDC Range:
-
200 to
+
200
°
C
Std. span: 200
°
C
10mV/
°
C
Range:
-
50 to
+
150
°
C
5
m
V/
°
C
Range:
-
100 to
+
200
°
C
Density
0.0000 to 6.0000g/ml
Com-
puting
accuracy
ULTRA
mass
MKII
(CN series)
Density before corr.
±
0.001g/ml (Factory calib. accuracy: Option)
Corrected density
±
0.002g/ml (with 4 to 20mA or 1 to 5VDC temp. input)
±
0.006g/ml (with temp. input from Pt 100
Ω
at 0
°
C,
3-wire) (
※
3)
Temperature
Pt 100
Ω
at 0
°
C
±
0.3%
4 to 20mADC or 1 to 5VDC
±
0.1% of span
10mV/
°
C
5
m
V/
°
C
Total flow of solids content
±
0.2% of R.D.
Clock IC battery backup
Lithium battery Battery life: 10 years approx.
Communication (when communica-
tion interface is provided.)
Interface: RS485 Multipoint (Up to 16 units can be connected.)
Dedicated protocol Baud rate: 4800 bps standard 9600 bps max.
Transmission cable
Use 3-conductor shielded cable to the resistance thermometer bulb.
Loop resist. 5
Ω
max. Example: 300 meters max. with 3-conductor 1.25mm
2
cable; 500 meters with 2.0mm
2
cable
Power source
85 to 264VAC, 50/60Hz or 20 to 30VDC
Power consumption
20W max.
Ambient temperature
-
10 to
+
50
°
C
Mounting
Panel mount
Finish
Munsell N1.5
Weight
2.5 kilograms, approx.
NOTES (
※
1): ST display stands for Super Twisted Nematic display.
(
※
2): Backlight life (luminance declined to one half its original luminance): 2500 hours, approx.
(
※
3): Depends on the accuracies of temperature input and density expansion coefficient of the fluid
to the uncorrected density. (Accuracy is shown where density change is constant to the differ-
ence between the temperature input and reference temperature.)