E-886-2-E

1

6. INTERNAL COMPONENTS AND FUNCTIONS

6.1 Front Panel
6.1.1 Display

The display is a 128 

×

 128-dot multiple function display capable of showing the data, units of measure, 

error messages, and other information at the same time. (The display is backlighted.)

6.1.2 Front Panel Keypad

The eight front panel key switches consist of two kinds of keys - functions keys and shift keys.

Function keys: Four round keys

Mainly used for function selection, such as activating the input conditions selected and reconfiguration.

Shift keys:  Four triangular keys

Used for moving the cursor, moving between menu items, or changing numerical values.

6.1.3 Error Messages

When an erratic condition arises, an error message automatically appears on the display. 

NOTE:  The information represented by error messages are listed on page 19.)

If two or more concurrent errors are involved, individual messages will be scrolled at intervals 

of approximately 3 seconds. When an error condition disappears, an error message automati-

cally goes out and the normal display is resumed.

NOTE:  An error logging function can store a maximum of 20 events each of which consists of year, 

month, day, hour and minutes of error occurrence and recovery. 

(

Complete details are covered in the Key Operation Manual.)

MODEL

EL4001

RUN

Fig. 6.1 Front Panel Keys

Function Keys

Shift Keys

Fig. 6.2 Touch Key Operation

Summary of Contents for EL4301

Page 1: ...of these instruments Keep this manual for ready reference It is suggested that the instruction manuals for the companion pulse generator flowmeter and receiving instrument be referred to at the same...

Page 2: ...OMPONENTS AND FUNCTIONS 12 6 1 Front Panel 12 6 1 1 Display 12 6 1 2 Front Panel Keypad 12 6 1 3 Error Messages 12 6 1 4 Display Items 13 7 CALCULATION FORMULAS 15 8 PREPARATIONAL CHECKS AND OPERATION...

Page 3: ...170 9 ABOUT EL4501 175 10 DIP SWITCH CONFIGURATION 182 Model with communication capabilities COMMUNICATION MANUAL Ins No E 880CM E CONTENTS 1 COMMUNICATION CAPABILITY OVERVIEW 5 2 NETWORK CONFIGURATI...

Page 4: ...d 11 When you inquire supply complete infor mation as to the product name model number product number ratings and other pertinent information 1 2 Transportation Precautions 1 In order to safeguard aga...

Page 5: ...nd provide an analog output EL4321 EL4331 This instrument receives density frequency signal from the density sensor and provides an analog output in proportion to the density of metered process fluid...

Page 6: ...0 centimeters from the back panel of the instrument to facilitate wiring and servicing 3 2 2 Panel 1 Use a rigid steel sheet with a minimum thickness of 1 6 millimeters 3 2mm thick is recommended 2 If...

Page 7: ...r circuits to minimize the possibility of inductive interference 3 Using crimp type lugs for wiring ensure good electrical coannections Terminals are found on the back of the instrument Fig 4 1 4 3 De...

Page 8: ...3 0V 14 0V 4 OUT 1 1 15 5 b Temp in 16 6 B 17 Temp in 7 A 18 Comm 1 8 19 9 20 Comm 2 10 Alarm out 21 11 NOTE Model provided with communication interface NOTE If transmitter MT9411 temperature termina...

Page 9: ...Pulse out 3 No polarity Alarm out Static relay 11 12 Density in SUP 13 SIG Tube period signal 5V square wave 14 0V TB2 No Label Description 1 2 3 4 Analog out Instant solids content flow 4 to 20mADC...

Page 10: ...Code Description Model E L 4 3 1 1 Density Computer for Mass Flowmeter with solids content calculation feature Power 6 20 to 30VDC Power consumption 20W max 7 85 to 264VAC 50 60Hz Temperature Input 0...

Page 11: ...1 Density corrected for temperature and pressure 9 Other than above special Communication Capability 0 No 1 Yes Finish 1 Munsell N1 5 Table 5 4 EL4331 Product Code Explanation Item Product Code Descr...

Page 12: ...ving between menu items or changing numerical values 6 1 3 Error Messages When an erratic condition arises an error message automatically appears on the display NOTE The information represented by err...

Page 13: ...plays it If it exceeds preset high or low limit its default fallback value is shown Total Mass Flowrate TOTAL COUNT Displays mass flow corrected for meter error Total Mass Flow of Solid Content TOTAL...

Page 14: ...re pressure and density currently coming in and displays it Specific Weight SPECIFIC WEIGHT Calculates specific weight based on the temperature pressure and density currently coming in and displays it...

Page 15: ...Xs Da Db Dx Dc Dx2 Ta Tb tx Tc tx2 100 where Xs Solids proportion Da to Dc Ta to Tc Coefficients to determine Xs Instant flowrate of solids content EL4311 Xs E Qsr Qr kg h Qr a f 1 3600 kg h 100 100 w...

Page 16: ...instrument operates with no fluid flow How to Check 1 Couple sources of simulated temperature and pressure signals 2 Using the shift keys select menu items and verify the information displayed NOTE Se...

Page 17: ...ulty 2 Pressure transmitter is faulty 3 A fault in internal assembly Faulty meter error correction factor and or temperature correction factor 1 Temperature and pressure readings correct 1 A fault in...

Page 18: ...2 OVER Analog pressure input 2 overflow 25 PRESS 2 UNDER Analog pressure input 2 underflow 26 DENSITY OVER Density input overflow 27 DENSITY UNDER Density input underflow 28 4mA SCALER 1 UNDER Analog...

Page 19: ...Std Span 200 C 10mV C Range 50 to 150 C 5 V C Range 100 to 200 C Density 0 0000 to 6 0000g ml Com puting accuracy ULTRA mass MKII CN series Density before correction 0 001g ml Factory calibration acc...

Page 20: ...cimal place Solids content proportion To the 2nd decimal place Error alarm Number of errors error messages Com puting range Temperature Pt 100 at 0 C Range 50 to 200 C Std span 70 C 4 to 20mADC or 1 t...

Page 21: ...ted Pressure To the 4th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error...

Page 22: ...th decimal place when MPa is selected Molecular weight To the 3rd decimal place when g mol is selected Specific weight To the 3rd decimal place Error alarm Number of errors error messages Com puting r...

Page 23: ...r Multi plexer Press Input Ckt analog Temp Input Ckt analog Temp Input Ckt Pt Analog Output Circuit Pulse Output Circuit 1 Pulse Output Circuit 2 Pulse Output Circuit 3 I O Board CPU Board Communicati...

Page 24: ...E 886 2 E All specifications are subject to change without notice for improvement 2017 01 Revised 2008 08 Released E 886 2 E 1...

Reviews: