2
3
IMPORTANT:
Read these Instructions for use carefully before connecting the regulato
to the gas cylinder or operating any appliance.
Keep these instructions for future reference.
INSTRUCTIONS FOR INSTALLATION
1)
Ensure that all taps are turned off on the gas appliance and on the regulator (turn clockwise towards (-)).
2)
Attach the hose to the regulator and to the gas appliance respectively.
The hose is equipped with ¼ “ left hand threads and can be threaded directly onto the regulator
and the gas inlet connection on the gas appliance. Hand tight plus ¼ of a turn.
3)
Thread the gas cartridge onto the regulator. Hand tight only.
4)
Open tap fully on the regulator (turn anticlockwise towards (+)).
•
When the regulator is to be used outdoors, it shall be positioned or protected against direct penetration
by any trickling water.
•
Check that seals (between the regulator and the gas cartridge) are in place and in good condition before
connecting to the gas cartridge.
•
Inspect seal before using the regulator
•
Check for leaks at all joints using soapy water.
NEVER USE A NAKED FLAME TO CHECK FOR LEAKS.
•
Do not use the regulator if it has damaged or worn seals.
•
Do not use a regulator which is leaking, damaged or which does not operate properly.
Seal
Outlet
connection
Hose
Tap
Inlet connection
UK: INSTRUCTION MANUAL
UK: INSTRUCTION MANUAL
Trinidad Gas Regulator Il
Model:
650827 / A500i-P158
Type of gas:
Butane
Supply pressure:
0.3 - 16 bar
Regulated pressure:
50 mbar
Flow rate:
0.8 kg/h
Inlet connection:
7/16”
Outlet connection:
¼ “ LH thread
Type of connections (inlet/outlet):
G35/H19
Harmonized standard
EN 16129
TRINIDAD GASSREGULATOR I + III
Summary of Contents for TRINIDAD GAS REGULATOR II