background image

6 | 

P a g e

 

 

Colonial Table Setup 

1.

 

Remove all components from packaging and 
inspect for damage or missing parts.  

2.

 

Place the fiberglass table base in your desired 
location on flat, level ground.  

3.

 

Viewing the base from above, place a riser piece 

on each corner of the base as shown below

.  

 

 

 

 

 

 

 

 

3a

.

 

Insert a screw into each 

riser to attach to the table 
base.  

DO NOT OVERTIGHTEN 

This may cause stripping. If 
stripping occurs, remove 
screw and move the riser at 
least ½” in any direction 
before putting the screw back 
in.  

4. With help from another person, gently set concrete 
top onto the base and center it. If the top doesn’t sit 
flat, rotate it until it sits evenly. For a more permanent 
installation, an outdoor-rated construction adhesive or 
silicone can be used to attach the top to the base.   

5. Gently lower your crystal fire burner into the burner 
cutout and continue to the next page for gas hookup 
and igniter hookup instructions.   

Summary of Contents for Colonial

Page 1: ...1 P a g e Colonial and Grand Colonial Fire Pit Tables Installation Instructions ...

Page 2: ... 8 Placing propane tank and finishing touches 12 Required Tools Utility Knife To cut and remove packaging 2 Open Ended Wrenches To make gas connections Leather Gloves To protect hands from rough edges found on the coffee table One 1 AAA Battery not included Required for piezoelectric igniter installation Electric screw gun 90220 C 5 24 2012 ...

Page 3: ...model you purchased turn to the corresponding page in this manual for installation instructions Base Supercast Tabletop with center burner cover Instructions begin on next page Flip to page 6 for assembly instructions Risers 4 Screws 4 Grounding wire x1 Grounding wire x1 Grounding wire may not be used depending on igniter included with your burner See P 8 for more information ...

Page 4: ...earance to combustibles 3 Place top on base as shown 4 Line top up with base as shown Holes in tabletop frame are also used for an alternate installation so not every hole will line up directly centered in each corner of the base This is normal as only 4 of these holes are used in this installation A solid line in the diagram at right indicates the approximate location of the holes used for mounti...

Page 5: ...rner of the base insert a mounting clip into mounting hole refer to image at right 5 Insert one of the included screws through the hole in the mounting clip and screw into the table base Do not over tighten as this may cause stripping If stripping occurs rotate the top approximately 1 and re insert all screws Unused screw hole For gas hookup instructions turn to page 7 ...

Page 6: ...ERTIGHTEN This may cause stripping If stripping occurs remove screw and move the riser at least in any direction before putting the screw back in 4 With help from another person gently set concrete top onto the base and center it If the top doesn t sit flat rotate it until it sits evenly For a more permanent installation an outdoor rated construction adhesive or silicone can be used to attach the ...

Page 7: ...with flexible metal gas line from the valve to the underside of burner It is not recommended to use Teflon tape or pipe dope on the connection to the valve with flare fittings LPG installations use the hose and regulator provided with the burner For Natural Gas hookup information and any other info not listed here consult your Crystal Fire owner s manual Read and understand your Crystal Fire burne...

Page 8: ... wire connection prongs on the back glossy side If one prong is present see below otherwise turn to page 10 for instructions on how to install and use a two pronged igniter Step 2 Disassemble igniter by unscrewing button cap followed by plastic nut Step 3 place looped end of grounding wire onto your igniter As shown Step 1 Make sure the valve is in the OFF position ...

Page 9: ... hexagonal nuts on the bottom of your Crystal Fire locations shown at right Loosen one of these nuts and slide the free forked end of the grounding wire onto it and re tighten the nut Your igniter is now grounded Test system by depressing the button on the igniter A continuous repeating spark between the igniter electrode and spark receiving probe means everything is connected properly Consult the...

Page 10: ...w sparker cap and hex nut sparker included with burner Install as shown below Wall of base If your Crystal Fire burner included a double pronged igniter there will be a grounding wire attached to the bottom of your burner bowl and the included grounding wire with your Colonial will not be used ...

Page 11: ...e end of the grounding wire should be secured to the underside of the burner by loosening one of the nuts on the bottom of the burner and inserting the plug as shown before re tightening the nut Test system by depressing the button on the igniter A continuous repeating spark between the igniter electrode and spark receiving probe means everything is connected properly Consult the troubleshooting s...

Page 12: ...ase with adequate clearance to burner so the two are not touching 3 Confirm all hoses are clear and not touching the burner Finishing touches Once fire pit is set up and in the desired position scatter decorative glass on burner surface forming an even layer of beads DO NOT BURN WITHOUT GLASS OR OTHER DECORATIVE SUBSTRATE PRESENT ...

Page 13: ...oper tightening of connections with two wrenches and full burner setup and lighting instructions DO NOT ATTEMPT TO INSTALL CF 20 BURNER WITHOUT FIRST CONSULTING THE MANUAL IF YOU ARE UNSURE OF HOW TO COMPLETE THE STEPS OUTLINED CONSULT A QUALIFIED TECHNICIAN WARNING After consulting the manual and following instructions remember before operating all gas connections must be fully checked for leaks ...

Page 14: ...14 P a g e Warranty Fire pit tables are covered under a 1 year manufacturer s warranty Please visit http www outdoorrooms com warranty form to register your product ...

Page 15: ...15 P a g e ...

Page 16: ...16 P a g e 2012 The Outdoor GreatRoom Company ...

Reviews: