11 |
P a g e
3.
To properly install ignition system, a spark and ground wire
need to be attached to the igniter box.
Start by plugging the black wire hanging from the
burner in to one side of the back of the igniter.
Plug the included grounding wire in to the back of the
sparker box. The free end of the grounding wire should
be secured to the underside of the burner by loosening
one of the nuts on the bottom of the burner and
inserting the plug as shown before re-tightening the
nut.
Test system by depressing the button on the igniter. A
continuous repeating spark between the igniter
electrode and spark-receiving probe means everything
is connected properly. Consult the troubleshooting
section of your crystal fire owner’s manual if spark is
weak, intermittent, or not present.