900-0213-01-00 REV B
Do not copy or distribute without permission.
Wiring
AC
Main Panel,
Grounded,
with
AC Source
AC
Subpanel
with Loads
Battery Bank
MATE3s System
Display
On/Off
Switch
or
Rapid
Shutdown
Also
Remove
On/Off Jumper
Auxiliary Device
or Generator Start
(if used)
AC
Bypass Interlock
(if used)
With Shunt (if used)
When installing a shunt for use with the FLEXnet DC
or a similar battery monitor, remove the ground lug .
Attach the shunt using the threaded holes .
The shunt connects to the negative terminal as in .
The negative cable connects to the shunt.
1
2
2
1
2
2
3
3
FXR Inverter
L1
N
L1
N
RTS