A minimum of one horizontal and one vertical dimensions are
necessary to validate the scale.
4.2 Preparing the Subfloor
- Clean and remove any debris, or protruding objects that could damage the
heating cable;
- Subfloor cracks must be filled with polyester wood filler (only for self-leveller);
- The subfloor must be solidly fastened in place to prevent movement;
- The application of a floor levelling product is recommended to prevent future
damage to the ceramic caused by subfloor movement;
- For concrete subfloors, apply a surface sealer that is compatible with electrical
heating systems in accordance with the cement glue manufacturer’s
instructions. Completely coat the surface;
- Let dry before installing the
Therma Cable
system (refer to the sealer's
instructions for drying time).
4.3 Marking the Floor
Felt marker
13
Fig. 4.3 a