Ottobock | 21
Safety instructions
ParaGolfer
Despite of compliance with all applicable EMC direc-
tives and standards, the power wheelchair can be af-
fected by interference from other electric devices (e.g.
department store EAS systems) or cause interference
to such devices. If you notice such a behaviour, move
your power wheelchair outside the interference range.
2.8.3 Interference immunity of this power wheelchair
INFORMATION
20 volts per meter (V/m) is a generally achievable and
useful immunity level against interference from radio wave
sources (as of May 1994) (the higher the level, the greater
the protection).
INFORMATION
This sports wheelchair model as shipped, with no further
modification, has an immunity level of 20 V/m.
2.9 Safety functions
INFORMATION
In dangerous situations, the ParaGolfer can be turned off
at any time using the on/off button. When the button is
pressed, the sports wheelchair brakes immediately and
the electric functions will be stopped.
If any malfunctions occur such as an insufficient supply of
energy to the brake, the software will recognise them and
trigger the emergency stop brake or reduce the speed of
the sports wheelchair. At the same time, a warning signal
will be emitted.
A tilt sensor is mounted in the centre of gravity of the Para-
Golfer; if the allowable side tilt angle is exceeded, an
acoustic and visual alarm signal is emitted.