8
NOTICE: Sensor input is RECOGNIZED as LOW when alarm signal is on a level with GND, and it is
recognized as HIGH when alarm signal is FLOATING or 5V. Following is internal circuit.
Thus, there is a danger of damage, when the sensor input goes to a Negative level or voltage higher than 5V.
5) Network Connection
DVR connects to LAN
◆
To view video image on the computer through internet with DVR view software.
6) HDD connection
Notice:
-The 16 ch DVR provides 2 internal hard drives. We provide one hard disk drive with removable rack; the
other one is fixed designed.
-We recommend you to set the Removable Hard Disk as Slave. Set the other one as the Master.
Internal Circuit
1.
Make sure the HDD is MASTER.
2.
Make sure the cable connector is
correct.
3.
MASTER set up, please check the
HDD panel.
1.
Make sure the HDD is MASTER and
SLAVE.
2.
Make sure the cable connector is correct.
3. MASTER and SLAVE set up, please check
the HDD panel.